In vivo glucose sensing for diabetes management: progress towards non-invasive monitoring

被引:40
作者
Pickup, J [1 ]
McCartney, L
Rolinski, O
Birch, D
机构
[1] Univ London Kings Coll, Dept Chem Pathol, London, England
[2] Guys Hosp, St Thomass Sch Med, London SE1 9RT, England
[3] Univ Strathclyde, Dept Phys & Appl Phys, Glasgow G4 0NG, Lanark, Scotland
关键词
D O I
10.1136/bmj.319.7220.1289
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A device for continuous in vivo monitoring of glutose concentration in people with diabetes has been a clinical and research priority for many years but now has an urgency which is probably unquestioned in diabetes tare. The purpose of this article is to explain recent advances in technology that are bringing glutose sensors closer to routine use and to highlight some of the remaining problems. Important new technologies include artificial receptors for glutose, tissue fluid sampling techniques, and new approaches to non-invasive sensing, such as fluorescence lifetime measurements.
引用
收藏
页码:1289 / U31
页数:4
相关论文
共 43 条
[11]   SUBCUTANEOUS IMPLANTATION OF A FERROCENE-MEDIATED GLUCOSE SENSOR IN PIGS [J].
CLAREMONT, DJ ;
SAMBROOK, IE ;
PENTON, C ;
PICKUP, JC .
DIABETOLOGIA, 1986, 29 (11) :817-821
[12]   EVALUATION OF A SUBCUTANEOUS GLUCOSE SENSOR OUT TO 3 MONTHS IN A DOG-MODEL [J].
GILLIGAN, BJ ;
SHULTS, MC ;
RHODES, RK ;
UPDIKE, SJ .
DIABETES CARE, 1994, 17 (08) :882-887
[13]   FREQUENCY OF SEVERE HYPOGLYCEMIA IN PATIENTS WITH TYPE-1 DIABETES WITH IMPAIRED AWARENESS OF HYPOGLYCEMIA [J].
GOLD, AE ;
MACLEOD, KM ;
FRIER, BM .
DIABETES CARE, 1994, 17 (07) :697-703
[14]   DEVELOPMENT OF A MINIATURIZED GLUCOSE MONITORING-SYSTEM BY COMBINING A NEEDLE-TYPE GLUCOSE SENSOR WITH MICRODIALYSIS SAMPLING METHOD - LONG-TERM SUBCUTANEOUS TISSUE GLUCOSE MONITORING IN AMBULATORY DIABETIC-PATIENTS [J].
HASHIGUCHI, Y ;
UEMURA, T ;
SAKAKIDA, M ;
KAJIWARA, K ;
NISHIDA, K ;
SHICHIRI, M .
DIABETES CARE, 1994, 17 (05) :387-396
[15]   Plastic antibodies: developments and applications [J].
Haupt, K ;
Mosbach, K .
TRENDS IN BIOTECHNOLOGY, 1998, 16 (11) :468-475
[16]   Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors [J].
Heinemann, L ;
Schmelzeisen-Redeker, G .
DIABETOLOGIA, 1998, 41 (07) :848-854
[17]  
Hoss U, 1998, DIABETOLOGIA, V41, pA45
[18]  
JAMES TD, 1994, ANGEW CHEM INT EDIT, V33, P2207, DOI 10.1002/anie.199422071
[19]   CHARACTERIZATION BY MICRODIALYSIS OF INTERCELLULAR GLUCOSE LEVEL IN SUBCUTANEOUS TISSUE IN HUMANS [J].
JANSSON, PA ;
FOWELIN, J ;
SMITH, U ;
LONNROTH, P .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (02) :E218-E220
[20]   NONINVASIVE MEASUREMENT OF BLOOD-GLUCOSE CONCENTRATIONS BY ANALYZING FOURIER-TRANSFORM INFRARED ABSORBENCY SPECTRA THROUGH ORAL-MUCOSA [J].
KAJIWARA, K ;
UEMURA, T ;
KISHIKAWA, H ;
NISHIDA, K ;
HASHIGUCHI, Y ;
UEHARA, M ;
SAKAKIDA, M ;
ICHINOSE, K ;
SHICHIRI, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 :S17-S22