Fluorescence detection in (sub-)nanoliter microarrays

被引:9
作者
van den Doel, LR [1 ]
Vellekoop, MJ [1 ]
Sarro, PM [1 ]
Picioreanu, S [1 ]
Moerman, R [1 ]
Frank, J [1 ]
van Dedem, G [1 ]
Hjelt, KT [1 ]
van Vliet, LJ [1 ]
Young, IT [1 ]
机构
[1] Delft Univ Technol, Fac Sci Appl, Pattern Recognit Grp, NL-2628 CJ Delft, Netherlands
来源
MICRO- AND NANOFABRICATED STRUCTURES AND DEVICES FOR BIOMEDICAL ENVIRONMENTAL APPLICATIONS II | 1999年 / 3606卷
关键词
microarrays; fluorescence microscopy; wide field imaging;
D O I
10.1117/12.350059
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The goal of our TU Delft interfaculty research program is to develop intelligent molecular diagnostic systems (IMDS) that can analyze liquid samples that contain a variety of biochemical compounds such as those associated with fermentation processes. One specific project within the IMDS program focuses on photon sensors. In order to analyze the liquid samples we use dedicated microarrays. At this stage, these are basically miniaturized micro titre plates. Typical dimensions of a vial are 200 x 200 x 20 mu m(3). These dimensions may be varied and the shape of the vials can be modified with a result that the volume of the vials varies from 0.5 to 1.6 nl. For all experiments, we have used vials with the shape of a truncated pyramid. These vials are fabricated in silicon by a wet etching process. For testing purposes the vials are filled with rhodamine solutions of various concentrations. To avoid evaporation glycerol-water (1:1, v/v) with a viscosity of 8.3 times the viscosity of water is used as solvent. We aim at wide field-of-view imaging at the expense of absolute sensitivity: the field-of-view increases quadratically with decreasing magnification. Small magnification, how ever, implies low Numerical Aperture (NA). The ability of a microscope objective to collect photons is proportional to the square of the NA. To image the entire microarray we have used an epi-illumination fluorescence microscope equipped with a low magnification (2.5 x / 0.075) objective and a scientific CCD camera to integrate the photons emitted from the fluorescing particles in the solutions in the vials. From these experiments we found that for this setup the detection limit is on the order of micromolar concentrations of fluorescing particles. This translates to 10(8) molecules per vial.
引用
收藏
页码:28 / 39
页数:12
相关论文
共 8 条
[1]  
[Anonymous], APPL FLUORESCENCE BI
[2]   Electrochemical analysis in picoliter microvials [J].
Clark, RA ;
Hietpas, PB ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :259-263
[3]   Detecting biomolecules in picoliter vials using aequorin bioluminescence [J].
Crofcheck, CL ;
Grosvenor, AL ;
Anderson, KW ;
Lumpp, JK ;
Scott, DL ;
Daunert, S .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4768-4772
[4]   Capillary flow as the cause of ring stains from dried liquid drops [J].
Deegan, RD ;
Bakajin, O ;
Dupont, TF ;
Huber, G ;
Nagel, SR ;
Witten, TA .
NATURE, 1997, 389 (6653) :827-829
[5]   SORTING SINGLE MOLECULES - APPLICATION TO DIAGNOSTICS AND EVOLUTIONARY BIOTECHNOLOGY [J].
EIGEN, M ;
RIGLER, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (13) :5740-5747
[6]   Calibration of micropipets using the bioluminescent protein aequorin [J].
Grosvenor, AL ;
Crofcheck, CL ;
Anderson, KW ;
Scott, DL ;
Daunert, S .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :3115-3118
[7]  
MULLIKIN JC, 1994, P SOC PHOTO-OPT INS, V2173, P73, DOI 10.1117/12.175165
[8]  
Rost F. W. D, 1992, FLUORESCENCE MICROSC, V1