Acute rupture of the descending thoracic aorta: Repair with use of endovascular stent-grafts

被引:181
作者
Semba, CP [1 ]
Kato, N [1 ]
Kee, ST [1 ]
Lee, GK [1 ]
Mitchell, RS [1 ]
Miller, DC [1 ]
Dake, MD [1 ]
机构
[1] STANFORD UNIV,MED CTR,SCH MED,DIV CARDIOTHORAC SURG,STANFORD,CA 94305
关键词
aorta; grafts and prostheses; rupture; stents and prostheses;
D O I
10.1016/S1051-0443(97)70568-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To describe the use of endovascular stent-grafts to treat acute ruptures of the descending thoracic aorta as an alternative to surgery in high-risk patients. MATERIALS AND METHODS: From July 1992 to August 1996, 95 patients underwent stent-grafting of the descending thoracic aorta for a variety of lesions. Of these, 11 patients with acute (less than or equal to 7 days) rupture from aneurysms (n = 8) or trauma (n = 3) underwent repair with use of endovascular stent-grafts. Rupture was confirmed with preoperative imaging studies and occurred in the mediastinum (n = 9), the pleural space (n = 1), or the lung (n = 1), All patients were considered high surgical risk due to generalized cardiopulmonary disease and/or previous thoracotomies. Stent-grafts were constructed from Z stents covered with polyester fabric and delivered through a catheter under fluoroscopic control from a remote access site. RESULTS: Stent-graft deployment was successful in all patients. There were no complications of perigraft leak, stent migration, paraplegia, or intraoperative death. Two patients died in the follow-up period: one of ventricular perforation during unrelated thoracic surgery for tumor resection (day 1) and one of cardiac arrest (day 28). All others are alive (mean follow-up, 15.1 months). CONCLUSION: For acute rupture of the thoracic aorta, endovascular stent-graft repair is technically feasible and may be a therapeutic alternative to a surgical interposition graft in patients considered high risk for conventional thoracotomy. Long-term studies are necessary to determine the role of stent-grafts in preventing future aortic rupture.
引用
收藏
页码:337 / 342
页数:6
相关论文
共 18 条
[1]   SALVAGE ABILITY OF PATIENTS WITH POSTTRAUMATIC RUPTURE OF DESCENDING THORACIC AORTA IN A PRIMARY TRAUMA CENTER [J].
BODILY, K ;
PERRY, JF ;
STRATE, RG ;
FISCHER, RP .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1977, 17 (10) :754-760
[2]   Endovascular stent-graft exclusion of an aortobronchial fistula [J].
Chuter, TAM ;
Ivancev, K ;
Lindblad, B ;
Brunkwall, J ;
Aren, C ;
Risberg, B .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (03) :357-359
[3]  
COWLEY RA, 1990, J THORAC CARDIOV SUR, V100, P652
[4]   RUPTURED ANEURYSM OF THE DESCENDING THORACIC AND THORACOABDOMINAL AORTA - ANALYSIS ACCORDING TO SIZE AND TREATMENT [J].
CRAWFORD, ES ;
HESS, KR ;
COHEN, ES ;
COSELLI, JS ;
SAFI, HJ .
ANNALS OF SURGERY, 1991, 213 (05) :417-426
[5]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[6]  
DEBAKEY ME, 1978, J CARDIOVASC SURG, V19, P571
[7]   ENDOVASCULAR STENT-GRAFTING AFTER ARCH ANEURYSM REPAIR USING THE ELEPHANT TRUNK [J].
FANN, JI ;
DAKE, MD ;
SEMBA, CP ;
LIDDELL, RP ;
PFEFFER, TA ;
MILLER, DC .
ANNALS OF THORACIC SURGERY, 1995, 60 (04) :1102-1105
[8]   Use of a self-expanding vascular occluder for embolization during endovascular aortic aneurysm repair [J].
Kato, N ;
Semba, CP ;
Dake, MD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (01) :27-33
[9]   Embolization of perigraft leaks after endovascular stent-graft treatment of aortic aneurysms [J].
Kato, N ;
Semba, CP ;
Dake, MD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (06) :805-811
[10]   DELAYED RUPTURE OF AORTIC-ANEURYSMS FOLLOWING ENDOVASCULAR STENT GRAFTING [J].
LUMSDEN, AB ;
ALLEN, RC ;
CHAIKOF, EL ;
RESNIKOFF, M ;
MORITZ, MW ;
GERHARD, H ;
CASTRONUOVO, JJ .
AMERICAN JOURNAL OF SURGERY, 1995, 170 (02) :174-178