Kinetic plot method as a tool to design coupled column systems producing 100,000 theoretical plates in the shortest possible time

被引:58
作者
Cabooter, Deirdre [1 ]
Lestremau, Francois [2 ]
Lynen, Frederic [3 ]
Sandra, Pat [3 ]
Desmet, Gert [1 ]
机构
[1] Vrije Univ Brussels, Dept Chem Engn, B-1050 Brussels, Belgium
[2] Pfizer Global Res & Dev, Analyt Res & Dev, Sandwich, Kent, England
[3] PARC, B-9000 Ghent, Belgium
关键词
Kinetic plot method; 100,000 plates; Acquity; Halo; Coupled columns;
D O I
10.1016/j.chroma.2008.09.106
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present paper reports on the possibility to use the kinetic plot method (KPM) to select and design the best possible system to achieve a given number (100,000) of theoretical plates for a pharmaceutical test mixture, using the information obtained from a series of single Column performance measurements of sub-2 mu m and supra-2 mu m porous shell particles conducted at three different temperatures and using mixtures of acetonitrile and 0.1% formic acid in water as the mobile phase. Because the KPM involves an extrapolation to different column lengths, the quality of the design was subsequently verified by coupling several columns to achieve the optimal total column length and run the actual analysis at the calculated optimal flow rate. The prediction error was generally better than 10%, with a slightly better prediction for to and N than for the retention time t(R). The sub-2 mu m and the porous shell particle coupled column systems achieve the 100,000 plates about equally fast, despite the fact that the former were used at 1000 bar and the latter only at 600 bar. The high temperature Operation (80 degrees C) yielded the fastest separation in both cases, allowing to reach 100,000 plates for a component eluting at k'=2.5 in only about 15 min. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:23 / 34
页数:12
相关论文
共 39 条
[1]  
ANTHIA FD, 1988, J CHROMATOGR, V435, P1
[2]   Approximate transient and long time limit solutions for the band broadening induced by the thin sidewall-layer in liquid chromatography columns [J].
Broeckhoven, Ken ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (01) :25-39
[3]   Use of the kinetic plot method to analyze commercial high-temperature liquid chromatography systems I: Intrinsic performance comparison [J].
Cabooter, D. ;
Heinisch, S. ;
Rocca, J. L. ;
Clicq, D. ;
Desmet, G. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) :121-133
[4]   Kinetic plot and particle size distribution analysis to discuss the performance limits of sub-2 μm and supra-2 μm particle columns [J].
Cabooter, Deirdre ;
Billen, Jeroen ;
Terryn, Herman ;
Lynen, Frederic ;
Sandra, Pat ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1204 (01) :1-10
[5]   Method to predict and compare the influence of the particle size on the isocratic peak capacity of high-performance liquid chromatography columns [J].
Cabooter, Deirdre ;
de Villiers, Andre ;
Clicq, David ;
Szucs, Roman ;
Sandra, Pat ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1147 (02) :183-191
[6]   Use of the kinetic plot method to analyze commercial high-temperature liquid chromatography systems - II. Practically constrained performance comparison [J].
Clicq, D. ;
Heinisch, S. ;
Rocca, J. L. ;
Cabooter, D. ;
Gzil, P. ;
Desmet, G. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1146 (02) :193-201
[7]   Fused-core particle technology as an alternative to sub-2-αm particles to achieve high separation efficiency with low backpressure [J].
Cunliffe, Jennifer M. ;
Maloney, Todd D. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (18) :3104-3109
[8]   Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1 mm ID columns [J].
de Villiers, A ;
Lauer, H ;
Szucs, R ;
Goodall, S ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1113 (1-2) :84-91
[9]   Evaluation of ultra performance liquid chromatography -: Part I.: Possibilities and limitations [J].
de Villiers, Andre ;
Lestremau, Francois ;
Szucs, Roman ;
Gelebart, Sylvie ;
David, Frank ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) :60-69
[10]  
Desmet G, 2005, LC GC EUR, V18, P403