Meta-analysis of the studies assessing temporal changes in coronary plaque volume using intravascular ultrasound

被引:35
作者
Rodriguez-Granillo, Gaston A. [1 ]
Agostoni, Pierfrancesco
Garcia-Garcia, Hector M.
Biondi-Zoccai, Giuseppe G. L.
Mc Fadden, Eugene
Amoroso, Giovanni
de Jaegere, Peter
Bruining, Nico
de Feyter, Pim
Serruys, Patrick W.
机构
[1] Erasmus MC, Thoraxctr, Dept Cardiol, Rotterdam, Netherlands
[2] Onze Lieve Vrouw Hosp, Amsterdam, Netherlands
[3] Otamendi Hosp, Dept Cardiovasc Imaging, Buenos Aires, DF, Argentina
[4] Antwerp Cardiovasc Ctr Middelheim, Antwerp, Belgium
[5] Policlin San Donato, Haemodynam & Cardiovasc Radiol Serv, Milan, Italy
关键词
D O I
10.1016/j.amjcard.2006.07.054
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the temporal effect of statin therapy on coronary atherosclerotic plaque volume measured by intravascular ultrasound (IVUS), we searched PubMed for eligible studies published between 1990 and January 2006. Inclusion criteria for retrieved studies were (1) IVUS volume analysis at baseline and follow-up and (2) statin therapy in >= 1 group of patients. All data of interest were abstracted in prespecified structured collection forms. Statistical analysis was performed with Review Manager 4.2. Random-effect weighted mean difference (WMD) was used as summary statistics for comparison of continuous variables. Nine studies of 985 patients (with 11 statin treatment arms) were selected. After a mean follow-up of 9.8 +/- 4.9 months, we found a significant decrease in coronary plaque volume (WMD -5.77 mm(3), 95% confidence interval -10.36 to -1.17, p = 0.01), with no significant heterogeneity across studies (p = 0.47). Prespecified subgroup analyses showed similar trends. Studies in which the achieved low-density lipoprotein (LDL) cholesterol level was < 100 mg/dl showed a trend for plaque regression (WMD -7.88 mm(3), 95% confidence interval -16.31 to 0.55, p = 0.07), whereas studies in which the achieved level of LDL cholesterol was >= 100 mg/dl, the trend was less evident (WMD -4.22 mm(3), 95% confidence interval -10.27 to 1.82, p = 0.17). Plaque volume remained essentially unchanged in patients not treated with statins (WMD 0.13 mm(3), 95% confidence interval -4.42 to 4.68, p = 0.96). In conclusion, statin therapy, particularly when achieving the target LDL level, appears to promote a significant regression of coronary plaque volume as measured by IVUS. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:5 / 10
页数:6
相关论文
共 29 条
[1]   A simple hint to improve Robinson and Dickersin's highly sensitive PubMed search strategy for controlled clinical trials [J].
Biondi-Zoccai, GGL ;
Agostoni, P ;
Abbate, A ;
Testa, L ;
Burzotta, F .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 2005, 34 (01) :224-225
[2]  
CLARKE MOA, 2003, COCHRANE DATABASE SY
[3]   Effects of aggressive versus conventional lipid-lowering therapy by simvastatin on human atherosclerotic lesions - A prospective, randomized, double-blind trial with high-resolution magnetic resonance imaging [J].
Corti, R ;
Fuster, V ;
Fayad, ZA ;
Worthley, SG ;
Helft, G ;
Chaplin, WF ;
Muntwyler, J ;
Viles-Gonzalez, JF ;
Weinberger, J ;
Smith, DA ;
Mizsei, G ;
Badimon, JJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) :106-112
[4]   Effect of vitamins C and E on progression of transplant-associated arteriosclerosis: a randomised trial [J].
Fang, JC ;
Kinlay, S ;
Beltrame, J ;
Hikiti, H ;
Wainstein, M ;
Behrendt, D ;
Suh, J ;
Frei, B ;
Mudge, GH ;
Selwyn, AP ;
Ganz, P .
LANCET, 2002, 359 (9312) :1108-1113
[5]   Rosuvastatin reduces MMP-7 secretion by human monocyte-derived macrophages: potential relevance to atherosclerotic plaque stability [J].
Furman, C ;
Copin, C ;
Kandoussi, M ;
Davidson, R ;
Moreau, M ;
McTaggart, B ;
Chapman, MJ ;
Fruchart, JC ;
Rouis, M .
ATHEROSCLEROSIS, 2004, 174 (01) :93-98
[6]   Reproducibility of intravascular ultrasound and intracoronary Doppler measurements [J].
Gaster, AL ;
Korsholm, L ;
Thayssen, P ;
Pedersen, KE ;
Haghfelt, TH .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 53 (04) :449-458
[7]   Reproducibility of volumetric quantification in intravascular ultrasound images [J].
Hagenaars, T ;
Gussenhoven, EJ ;
van Essen, JA ;
Seelen, J ;
Honkoop, J ;
van der Lugt, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03) :367-374
[8]   Early experience with intravascular ultrasound in evaluating the effect of statins on femoropopliteal arterial disease: Hypothesis-generating observations in humans [J].
Hagenaars, T ;
Gussenhoven, EJ ;
Kranendonk, SE ;
Blankensteijn, JD ;
Honkoop, J ;
van der Linden, E ;
van der Lugt, A .
CARDIOVASCULAR DRUGS AND THERAPY, 2000, 14 (06) :635-641
[9]   Regression of coronary atherosclerosis by simvastatin - A serial intravascular ultrasound study [J].
Jensen, LO ;
Thayssen, P ;
Pedersen, KE ;
Stender, S ;
Haghfelt, T .
CIRCULATION, 2004, 110 (03) :265-270
[10]   Impact of lipid abnormalities in development and progression of transplant coronary disease: A serial intravascular ultrasound study [J].
Kapadia, SR ;
Nissen, SE ;
Ziada, KN ;
Rincon, G ;
Crows, TD ;
Boparai, N ;
Young, JB ;
Tuzcu, EM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (01) :206-213