摘要
Background-OCT can image plaque microstructure at a level of resolution not previously demonstrated with other imaging techniques because it uses infrared light rather than acoustic waves. Objectives-To compare optical coherence tomography (OCT) and intravascular ultrasound (IVUS) imaging of in vitro atherosclerotic plaques. Methods-Segments of abdominal aorta were obtained immediately before postmortem examination. Images of 20 sites from five patients were acquired with OCT (operating at an optical wavelength of 1300 nm which was delivered to the sample through an optical fibre) and a 30 MHz ultrasonic transducer. After imaging, the microstructure of the tissue was assessed by routine histological processing. Results-OCT yielded superior structural information in all plaques examined. The mean (SEM) axial resolution of OCT and IVUS imaging was 16 (1) and 110 (7), respectively, as determined by the point spread function from a mirror. Furthermore, the dynamic range of OCT was 109 dB compared with 43 dB for IVUS imaging. Conclusions-OCT represents a promising new technology for intracoronary imaging because of its high resolution, broad dynamic range, and ability to be delivered through intravascular catheters.
引用
收藏
页码:397 / 403
页数:7
相关论文
共 34 条
  • [1] ANGIOGRAPHIC PROGRESSION OF CORONARY-ARTERY DISEASE AND THE DEVELOPMENT OF MYOCARDIAL-INFARCTION
    AMBROSE, JA
    TANNENBAUM, MA
    ALEXOPOULOS, D
    HJEMDAHLMONSEN, CE
    LEAVY, J
    WEISS, M
    BORRICO, S
    GORLIN, R
    FUSTER, V
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (01) : 56 - 62
  • [2] Benkeser P J, 1993, J Am Soc Echocardiogr, V6, P158
  • [3] HIGH-RESOLUTION OPTICAL COHERENCE TOMOGRAPHIC IMAGING USING A MODE-LOCKED TI-AL2O3 LASER SOURCE
    BOUMA, B
    TEARNEY, GJ
    BOPPART, SA
    HEE, MR
    BREZINSKI, ME
    FUJIMOTO, JG
    [J]. OPTICS LETTERS, 1995, 20 (13) : 1486 - 1488
  • [4] Imaging of coronary artery microstructure (in vitro) with optical coherence tomography
    Brezinski, ME
    Tearney, GJ
    Bouma, BE
    Boppart, SA
    Hee, MR
    Swanson, EA
    Southern, JF
    Fujimoto, JG
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (01) : 92 - 93
  • [5] Optical coherence tomography for optical biopsy - Properties and demonstration of vascular pathology
    Brezinski, ME
    Tearney, GJ
    Bouma, BE
    Izatt, JA
    Hee, MR
    Swanson, EA
    Southern, JF
    Fujimoto, JG
    [J]. CIRCULATION, 1996, 93 (06) : 1206 - 1213
  • [6] HIGH-RESOLUTION REFLECTOMETRY IN BIOLOGICAL TISSUES
    CLIVAZ, X
    MARQUISWEIBLE, F
    SALATHE, RP
    NOVAK, RP
    GILGEN, HH
    [J]. OPTICS LETTERS, 1992, 17 (01) : 4 - 6
  • [7] DAVIES MJ, 1985, BRIT HEART J, V53, P363
  • [8] FALK E, 1983, BRIT HEART J, V50, P127
  • [9] EYE-LENGTH MEASUREMENT BY INTERFEROMETRY WITH PARTIALLY COHERENT-LIGHT
    FERCHER, AF
    MENGEDOHT, K
    WERNER, W
    [J]. OPTICS LETTERS, 1988, 13 (03) : 186 - 188
  • [10] ARTIFACTS IN INTRAVASCULAR ULTRASOUND IMAGING - ANALYSES AND IMPLICATIONS
    FINET, G
    MAURINCOMME, E
    TABIB, A
    CROWLEY, RJ
    MAGNIN, I
    RORIZ, R
    BEAUNE, J
    AMIEL, M
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (07) : 533 - 547