Low-osmolar gadodiamide as alternative contrast agent for diagnostic angiography and angiographic interventions in patients with renal insufficiency

被引:8
作者
Dinkel, HP
Hoppe, H
Baumgartner, I
Do, DD
Triller, J
机构
[1] Univ Klin Bern, Inselspital, Inst Diagnost Radiol, CH-3010 Bern, Switzerland
[2] Inselspital Bern, Abt Angiol, CH-3010 Bern, Switzerland
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2002年 / 174卷 / 01期
关键词
gadodiamid; gadolinium-DTPA; CO2-angiography; renal failure; digital subtraction angiography;
D O I
10.1055/s-2002-19535
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the benefit and feasibility of gadolinium contrast agents for intra-arterial use in diagnostic and therapeutic angiography in patients with renal insufficiency. Methods: In 15 patients with planned peripheral or renal vascular interventions digital subtraction angiography with intra-arterial administration of gadolinium (gadodiamide n = 14, gadolinium-DTPA n = 1) was performed. Gadolinium was used selectively after peripheral catheter placement, mainly as an adjunct to CO2 (n = 12), to assess the distal run-off vessels or to characterize stenotic lesions, Results: In 14 cases gadolinium yielded good or satisfactory results that were superior to those of CO2 angiography in the femoropopliteal region and calf, but also to the aorto-iliac vessels and the renal arteries. A small amount of iodinated contrast media was administered due to insufficient contrast of gadolinium in one patient. Mean serum creatinine level after angiography (295 +/- 167 mumol/l; range 125 - 764 mumol/l) was not significantly different (p greater than or equal to 0,37) from the initial level (279 +/- 149 pmol/l; range 143 - 728 mumol/l). Conclusion: Gadolinium is a viable alternative contrast agent for digital subtraction angiography and percutaneous transluminal angioplasty in patients with renal insufficiency. It enhances the diagnostic evaluation of stenosis and run-off vessels.
引用
收藏
页码:56 / 61
页数:6
相关论文
共 32 条
  • [1] Gadolinium-enhanced three-dimensional MR angiography before endovascular treatment of aneurysms in the abdominal aorta, iliac and peripheral vessels
    Biederer, J
    Link, J
    Steffens, JC
    Fronius, M
    Heller, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 985 - 991
  • [2] Stent placement under real-time MR control:: First experience in an animal model.
    Bücker, A
    Neuerburg, JM
    Adam, G
    Schürmann, K
    Rasche, V
    van Vaals, JJ
    Molgaard-Nielsen, A
    Günther, RW
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (06): : 655 - 657
  • [3] EXPERIMENTAL AND THEORETICAL X-RAY-IMAGING PERFORMANCE COMPARISON OF IODINE AND LANTHANIDE CONTRAST AGENTS
    CARDINAL, HN
    HOLDSWORTH, DW
    DRANGOVA, M
    HOBBS, BB
    FENSTER, A
    [J]. MEDICAL PHYSICS, 1993, 20 (01) : 15 - 31
  • [4] CO2 digital subtraction angiography: Potential complications and their prevention
    Caridi, JG
    Hawkins, IF
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (03) : 383 - 391
  • [5] THE CEREBROVASCULAR EFFECTS OF INTRAARTERIAL CO2 IN QUANTITIES REQUIRED FOR DIAGNOSTIC-IMAGING
    COFFEY, R
    QUISLING, RG
    MICKLE, JP
    HAWKINS, IF
    BALLINGER, WB
    [J]. RADIOLOGY, 1984, 151 (02) : 405 - 410
  • [6] Gadolinium dimeglumine: an alternative contrast agent for digital subtraction angiography
    Hammer, FD
    Goffette, PP
    Malaise, J
    Mathurin, P
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (01) : 128 - 136
  • [7] Different Spiral CT protocol types and their significance in the diagnosis of aortic dissections:: results of a prospective study.
    Hansmann, HJ
    Döbert, N
    Kücherer, H
    Richter, GM
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (11): : 879 - 887
  • [8] PRECLINICAL SAFETY ASSESSMENT AND PHARMACOKINETICS OF GADODIAMIDE INJECTION, A NEW MAGNETIC-RESONANCE-IMAGING CONTRAST AGENT
    HARPUR, ES
    WORAH, D
    HALS, PA
    HOLTZ, E
    FURUHAMA, K
    NOMURA, H
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 : S28 - S43
  • [9] TRIPLE-DOSE VERSUS STANDARD-DOSE GADOPENTETATE DIMEGLUMINE - A RANDOMIZED STUDY IN 199 PATIENTS
    HAUSTEIN, J
    LANIADO, M
    NIENDORF, HP
    LOUTON, T
    BECK, W
    PLANITZER, J
    SCHOFFEL, M
    REISER, M
    KAISER, W
    SCHORNER, W
    HIERHOLZER, J
    TRAUPE, H
    HAMM, B
    [J]. RADIOLOGY, 1993, 186 (03) : 855 - 860
  • [10] RENAL TOLERANCE OF GADOLINIUM-DTPA DIMEGLUMINE IN PATIENTS WITH CHRONIC-RENAL-FAILURE
    HAUSTEIN, J
    NIENDORF, HP
    KRESTIN, G
    LOUTON, T
    SCHUHMANNGIAMPIERI, G
    CLAUSS, W
    JUNGE, W
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 (02) : 153 - 156