User Configurable Microfluidic Device for Multiplexed Immunoassays Based on DNA-Directed Assembly

被引:30
作者
Schroeder, Hendrik [1 ]
Adler, Michael [2 ]
Gerigk, Katrin [4 ]
Mueller-Chorus, Birgit [3 ]
Goetz, Friedrich [4 ]
Niemeyer, Christof M. [1 ]
机构
[1] Tech Univ Dortmund, Fak Chem, D-44227 Dortmund, Germany
[2] Chimera Biotec GmbH, D-44227 Dortmund, Germany
[3] Boehringer Ingelheim microParts GmbH, D-44227 Dortmund, Germany
[4] Fachhsch Gelsenkirchen, D-45877 Gelsenkirchen, Germany
关键词
ANTIBODY MICROARRAYS; IMMOBILIZATION; STRATEGIES; ATTACHMENT; LIBRARIES;
D O I
10.1021/ac802228k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a microfluidic device for multiplexed immunoassays based on DNA-directed immobilization. Because of the versatile building blocks used for this technique, it is possible to build up user configurable protein microarrays within the microfluidic system by means of DNA-directed self-assembly, which can be used for immunoassay applications. We demonstrate the performance of our system by parallel detection of cytokines in a multiplex immunoassay, employing silver deposition labeling and optical read-out.
引用
收藏
页码:1275 / 1279
页数:5
相关论文
共 26 条
[1]  
ADLER M, UNPUB
[2]   DNA-encoded antibody libraries: A unified platform for multiplexed cell sorting and detection of genes and proteins [J].
Bailey, Ryan C. ;
Kwong, Gabriel A. ;
Radu, Caius G. ;
Witte, Owen N. ;
Heath, James R. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (07) :1959-1967
[3]   A study on photolinkers used for biomolecule attachment to polymer surfaces [J].
Dankbar, Daniela M. ;
Gauglitz, Guenter .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (7-8) :1967-1974
[4]   Solid-phase and bead-based cytokine immunoassay: A comparison [J].
de Jager, W ;
Rijkers, GT .
METHODS, 2006, 38 (04) :294-303
[5]   Microarray-based in vitro evaluation of DNA oligomer libraries designed in silico [J].
Feldkamp, U ;
Wacker, R ;
Schroeder, H ;
Banzhaf, W ;
Niemeyer, CM .
CHEMPHYSCHEM, 2004, 5 (03) :367-372
[6]   Development and validation of sandwich ELISA microarrays with minimal assay interference [J].
Gonzalez, Rachel M. ;
Seurynck-Servoss, Shannon L. ;
Crowley, Sheila A. ;
Brown, Marty ;
Omenn, Gilbert S. ;
Hayes, Daniel F. ;
Zangar, Richard C. .
JOURNAL OF PROTEOME RESEARCH, 2008, 7 (06) :2406-2414
[7]   Current development in microfluidic immunosensing chip [J].
Henares, Terence G. ;
Mizutani, Fumio ;
Hisamoto, Hideaki .
ANALYTICA CHIMICA ACTA, 2008, 611 (01) :17-30
[8]   Human protein atlas and the use of microarray technologies [J].
Hober, S. ;
Uhlen, M. .
CURRENT OPINION IN BIOTECHNOLOGY, 2008, 19 (01) :30-35
[9]   Chemical Strategies for Generating Protein Biochips [J].
Jonkheijm, Pascal ;
Weinrich, Dirk ;
Schroeder, Hendrik ;
Niemeyer, Christof M. ;
Waldmann, Herbert .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (50) :9618-9647
[10]   High-throughput antibody microarrays for quantitative proteomic analysis [J].
Lv, Lin-Li ;
Liu, Bi-Cheng .
EXPERT REVIEW OF PROTEOMICS, 2007, 4 (04) :505-513