High mass positive ions and molecules in capacitively-coupled radio-frequency CF4 plasmas

被引:41
作者
Schwarzenbach, W [1 ]
Cunge, G [1 ]
Booth, JP [1 ]
机构
[1] Univ Grenoble 1, CNRS, UMR 5588, Spectrometrie Phys Lab, F-38402 St Martin Dheres, France
关键词
D O I
10.1063/1.370555
中图分类号
O59 [应用物理学];
学科分类号
摘要
The positive ions and neutral radicals arriving at the earthed walls of a capacitively-coupled radio-frequency pure CF4 plasma were analyzed using a quadrupole mass spectrometer adapted for high masses. Experiments were performed at 50 and 200 mTorr, in an empty reactor and with Si and SiO2-coated Si substrates on the powered electrode. High mass ions and neutrals were detected, up to 500 and 300 amu, respectively. The abundance of high-mass species was greatest in the presence of silicon wafers and at higher pressure. The observed ion masses can be separated into distinct series, originating from different initial bases to which successive CF2 units have been added. We, therefore, propose that these high-mass species are the result of a gas phase polymerization process consisting of CF2 addition reactions, in agreement with a model proposed recently by our group. The influence of a silicon substrate derives primarily from the strong decrease that it induces in the concentration of F atoms, which otherwise limit the concentration of CF2 and of chain initiating species. (C) 1999 American Institute of Physics. [S0021-8979(99)05411-0].
引用
收藏
页码:7562 / 7568
页数:7
相关论文
共 48 条
[41]   Mass-resolved ion energy measurements at both electrodes of a 13.56MHz plasma in CF4 [J].
Snijkers, RJMM ;
vanSambeek, MJM ;
Hoppenbrouwers, MB ;
Kroesen, GMW ;
deHoog, FJ .
JOURNAL OF APPLIED PHYSICS, 1996, 79 (12) :8982-8992
[42]   Electron attachment mass spectroscopy as a diagnostics for electronegative gases and plasmas [J].
Stoffels, E ;
Stoffels, WW ;
Tachibana, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (01) :116-122
[43]   Electron attachment mass spectrometry for the detection of electronegative species in a plasma [J].
Stoffels, WW ;
Stoffels, E ;
Tachibana, K .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (7B) :4638-4643
[44]   Polymerization of fluorocarbons in reactive ion etching plasmas [J].
Stoffels, WW ;
Stoffels, E ;
Tachibana, K .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1998, 16 (01) :87-95
[45]   APPEARANCE MASS-SPECTROMETRY OF NEUTRAL RADICALS IN RADIO-FREQUENCY PLASMAS [J].
SUGAI, H ;
TOYODA, H .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1992, 10 (04) :1193-1200
[46]   LASER-INDUCED FLUORESCENCE MEASUREMENT AND ANALYTICAL MODEL FOR THE REACTION PROBABILITY OF CF2 ON SI [J].
THOMAN, JW ;
SUZUKI, K ;
KABLE, SH ;
STEINFELD, JI .
JOURNAL OF APPLIED PHYSICS, 1986, 60 (08) :2775-2777
[47]   EFFECT OF ADDED HYDROGEN ON THE RF DISCHARGE CHEMISTRY OF CF4, CF3H, AND C2F6 [J].
TRUESDALE, EA ;
SMOLINSKY, G .
JOURNAL OF APPLIED PHYSICS, 1979, 50 (11) :6594-6599
[48]   Kinetics of F atoms and fluorocarbon radicals studied by threshold ionization mass spectrometry in a microwave CF4 plasma [J].
Tserepi, A ;
Schwarzenbach, W ;
Derouard, J ;
Sadeghi, N .