Programmed temperature vaporiser-based injection in capillary gas chromatography

被引:40
作者
Engewald, W
Teske, J
Efer, J
机构
[1] Univ Leipzig, Inst Analyt Chem, Fac Chem & Mineral, D-04103 Leipzig, Germany
[2] Univ Leipzig, Inst Legal Med, D-04103 Leipzig, Germany
关键词
reviews; programmed temperature vaporisers; large-volume injection; injection methods;
D O I
10.1016/S0021-9673(99)00723-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of programmed temperature vaporisation (PTV) in capillary I:as chromatographic analysis is reviewed. The development of the different strategies as well as the state of the art are described. As the analytes are normally enriched in the PTV insert, the quoted papers are subdivided depending on whether the enrichment was carried out from organic solvents, from water or from gaseous media. Furthermore, the possibilities of PTVs for on-line coupling with sample preparation methods or other separation techniques and their use as thermoreactors are mentioned. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:259 / 278
页数:20
相关论文
共 115 条
[71]   ADSORPTION THERMAL-DESORPTION WITH SMALL CARTRIDGES FOR THE DETERMINATION OF TRACE AQUEOUS SEMIVOLATILE ORGANIC-COMPOUNDS [J].
PANKOW, JF ;
LIGOCKI, MP ;
ROSEN, ME ;
ISABELLE, LM ;
HART, KM .
ANALYTICAL CHEMISTRY, 1988, 60 (01) :40-47
[73]   AUTOMATIC HEADSPACE AND PROGRAMMED TEMPERATURE VAPORIZER (PTV) OPERATED IN CRYO-ENRICHMENT MODE IN HIGH-RESOLUTION GAS-CHROMATOGRAPHY [J].
POY, F ;
COBELLI, L .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1985, 23 (03) :114-119
[74]   A UNIVERSAL SAMPLE INJECTION SYSTEM FOR CAPILLARY COLUMN GC USING A PROGRAMMED TEMPERATURE VAPORIZER (PTV) [J].
POY, F ;
VISANI, S ;
TERROSI, F .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1982, 5 (07) :355-359
[75]   AUTOMATIC INJECTION IN HIGH-RESOLUTION GAS-CHROMATOGRAPHY - A PROGRAMMED TEMPERATURE VAPORIZER AS A GENERAL-PURPOSE INJECTION SYSTEM [J].
POY, F ;
VISANI, S ;
TERROSI, F .
JOURNAL OF CHROMATOGRAPHY, 1981, 217 (NOV) :81-90
[76]   COMPARISON OF THE PERFORMANCES OF HOT AND COLD SAMPLE INTRODUCTION WITH A PROGRAMMED-TEMPERATURE VAPORIZER IN THE SPLIT AND SPLITLESS MODES [J].
REGLERO, G ;
HERRAIZ, M ;
HERRAIZ, T ;
LOYOLA, E .
JOURNAL OF CHROMATOGRAPHY, 1988, 438 (02) :243-251
[77]   STATIC HEADSPACE GAS-CHROMATOGRAPHY OF RESIDUAL SOLVENTS IN PHARMACEUTICAL PRODUCTS [J].
RUSSO, MV .
CHROMATOGRAPHIA, 1994, 39 (11-12) :645-648
[78]  
Sandra P., 1997, INT ENV TECH, V7, P26
[79]   COLD SAMPLE INJECTION WITH EITHER THE SPLIT OR SPLITLESS MODE OF TEMPERATURE-PROGRAMMED SAMPLE TRANSFER - DESIGN AND TESTING OF A NEW, ELECTRICALLY HEATED CONSTRUCTION FOR UNIVERSAL APPLICATION OF DIFFERENT MODES OF SAMPLING [J].
SCHOMBURG, G ;
HUSMANN, H ;
BEHLAU, H ;
SCHULZ, F .
JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV) :251-258
[80]   COLD SAMPLE INJECTION WITH EITHER THE SPLIT OR SPLITLESS MODE OF TEMPERATURE-PROGRAMMED SAMPLE TRANSFER - COMPARISON TO COLD ON-COLUMN INJECTION WITH A COMMERCIAL DEVICE [J].
SCHOMBURG, G ;
HUSMANN, H ;
SCHULZ, F ;
TELLER, G ;
BENDER, M .
JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV) :259-267