Reduction of osteolysis with use of Marathon cross-linked polyethylene - A concise follow-up, at a minimum of five years, of a previous report

被引:54
作者
Bitsch, Rudi G. [1 ]
Loidolt, Travis [1 ]
Heisel, Christian [1 ]
Ball, Scott [1 ]
Schmalzried, Thomas P. [1 ]
机构
[1] Joint Replacement Inst, Los Angeles, CA USA
关键词
D O I
10.2106/JBJS.F.00991
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We previously reported wear data at a minimum of two years following thirty-four total hip replacements with a Marathon cross-linked polyethylene liner and twenty-four replacements with a conventional (gamma-sterilized-in-air) Enduron polyethylene liner. In this current study, with sequential five-year radiographs, wear rates were determined with use of linear regression analysis. The Marathon polyethylene had average wear rates of 15.4 mm(3)/yr and 8.0 mm(3)/million cycles. The Enduron polyethylene had average wear rates of 55.5 mm(3)/yr and 29.9 mm(3)/million cycles. The adjusted volumetric wear rate of the Marathon polyethylene was 73% lower than that of the Enduron polyethylene (p = 0.001). Osteolysis developed in eight of the twenty-four hips with an Enduron liner but was not apparent in any hip with a Marathon liner. Level of Evidence: Therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1487 / 1491
页数:5
相关论文
共 23 条
[11]
Short-term in vivo wear of cross-linked polyethylene [J].
Heisel, C ;
Silva, M ;
dela Rosa, MA ;
Schmalzried, TP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (04) :748-751
[12]
In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty [J].
Manning, DW ;
Chiang, PP ;
Martell, JM ;
Galante, JO ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :880-886
[13]
Determination of polyethylene wear in total hip replacements with use of digital radiographs [J].
Martell, JM ;
Berdia, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (11) :1635-1641
[14]
Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty [J].
Martell, JM ;
Berkson, E ;
Berger, R ;
Jacobs, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (06) :1111-1117
[15]
Current concepts review - Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty [J].
McCalden, RW ;
Naudie, DD ;
Yuan, XH ;
Bourne, RB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (10) :2323-2334
[16]
Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls [J].
McKellop, H ;
Shen, FW ;
DiMaio, W ;
Lancaster, JG .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (369) :73-82
[17]
Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene [J].
Muratoglu, OK ;
Merrill, EW ;
Bragdon, CR ;
O'Connor, D ;
Hoeffel, D ;
Burroughs, B ;
Jasty, M ;
Harris, WH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :253-262
[18]
Oonishi H, 2000, J Orthop Sci, V5, P223, DOI 10.1007/s007760050155
[19]
Comparison of femoral head penetration rates between cementless acetabular components with 22-mm and 28-mm heads [J].
Pedersen, DR ;
Callaghan, JJ ;
Johnston, TL ;
Fetzer, GB ;
Johnston, RC .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :111-115
[20]
Wear in total hip and knee replacements [J].
Schmalzried, TP ;
Callaghan, JJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :115-136