Current concepts review - Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty

被引:86
作者
McCalden, RW [1 ]
Naudie, DD [1 ]
Yuan, XH [1 ]
Bourne, RB [1 ]
机构
[1] Hlth Sci Ctr, Div Orthopaed Surg, London, ON N6A 5A5, Canada
关键词
D O I
10.2106/JBJS.E.00223
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
All wear-measurement techniques assess femoral head penetration and therefore cannot distinguish between true polyethylene wear and bedding-in. Multiple wear measurements that are made at different time-intervals after bedding-in has occurred are required to determine the true wear rate. Computer-assisted edge-detection techniques offer improved accuracy and precision compared with manual techniques and appear to be ideally suited for the retrospective and prospective examination of large groups of patients with intermediate to long-term radiographic follow-up (more than five years). While radiostereometric analysis offers improved accuracy and precision compared with computer-assisted edge-detection techniques, widescale clinical application is limited because of its relative expense, the required expertise, and the fact that it can only be used in a prospective fashion.
引用
收藏
页码:2323 / 2334
页数:12
相关论文
共 97 条
[1]
Technical feasibility and precision of radiostereometric analysis as an outcome measure in canine cemented total hip replacement [J].
Allen, MJ ;
Hartmann, SM ;
Sacks, JM ;
Calabrese, J ;
Brown, PR .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2004, 9 (01) :66-75
[2]
[Anonymous], CLIN ORTHOPAEDICS
[3]
*ASTM, 2004, F238504 ASTM
[4]
*ASTM, 2002, E17790A ASTM INT
[5]
*ASTM, 1999, E17790A ASTM
[6]
INSTABILITY AND WEAR OF TOTAL HIP PROSTHESES DETERMINED WITH ROENTGEN STEREOPHOTOGRAMMETRY [J].
BALDURSSON, H ;
EGUND, N ;
HANSSON, LI ;
SELVIK, G .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1979, 95 (04) :257-263
[7]
Radiographic wear measurements in a cementless metal-backed modular cobalt-chromium acetabular component [J].
Barrack, RL ;
Lavernia, C ;
Szuszczewicz, ES ;
Sawhney, J .
JOURNAL OF ARTHROPLASTY, 2001, 16 (07) :820-828
[8]
The precision of radiostereometric measurements.: Manual vs. digital measurements [J].
Börlin, N ;
Thien, T ;
Kärrholm, J .
JOURNAL OF BIOMECHANICS, 2002, 35 (01) :69-79
[9]
BORLIN N, 2000, THESIS UMEA U SWEDEN
[10]
Comparison of two digital radio stereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom [J].
Bragdon, CR ;
Estok, DM ;
Malchau, H ;
Kärrholm, J ;
Yuan, XH ;
Bourne, R ;
Veldhoven, J ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (03) :659-664