Automated on-line comprehensive two-dimensional LC x GC and LC x GC-ToF MS: Instrument design and application to edible oil and fat analysis

被引:58
作者
de Koning, S
Janssen, HG
van Deursen, M
Brinkman, UAT
机构
[1] Unilever Res Labs, Cent Analyt Sci, NL-3130 AC Vlaardingen, Netherlands
[2] LECO Instrumente, Separat Sci Grp, D-41199 Monchengladbach, Germany
[3] Netherlands Forens Inst, NL-2280 GC Rijswijk, Netherlands
[4] Free Univ Amsterdam, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
关键词
comprehensive two-dimensional chromatography; comprehensive LC x GC; LC x GC-ToF MS; edible fats and oils; triacylglycerides; triglycerides; TAG; fatty acid methyl esters; FAME;
D O I
10.1002/jssc.200301676
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
After a successful off-line feasibility study, the automation of comprehensively coupled liquid chromatography and gas chromatography (LC x GC) has been studied. Important aspects to consider when developing automated LG x GC include the relative speeds of the two dimensions, the compatibility of the LC eluent (type and flow rate) with the GC dimension, and the column loadabilities. Because the GC separation is relatively slow, the LC instrument has to be operated in the stop-flow mode. Two interfaces for transferring large numbers of subsequent LC fractions to the GC were constructed: one based on a six-port switching valve, and one which uses a dual side-port syringe. Both interfaces were found to perform fully acceptably. The actual transfer of the LC fraction to the GC was realised using a standard split injector to vaporise the compounds and LC eluent. Gas phase splitting was applied to match LC mass load and GC column loadability. The standard deviations of the peak areas obtained in this way were better than 7% (n = 6). The reliability of the system was demonstrated by the problem-free analysis of large series of oil and fat samples, with the focus on both intact triglycericles and their fatty acid methyl esters (FAMEs). Finally, the hyphenation of the automated LC x GC system to a sensitive and rapid-scanning time-of-flight mass spectrometer was realised. By using LC x GC-ToF MS, the information density of the chromatograms could be improved even further, which allowed easy identification of individual compounds as well as compound groups.
引用
收藏
页码:397 / 409
页数:13
相关论文
共 36 条
[1]  
[Anonymous], 1998, OFF METH REC PRACT, V5th
[2]   Measurement of reduced sulphur compounds contained in aqueous matrices by direct injection into a gas chromatograph with a flame photometric detector [J].
Bérubé, PR ;
Parkinson, PD ;
Hall, ER .
JOURNAL OF CHROMATOGRAPHY A, 1999, 830 (02) :485-489
[3]   Large-volume injection in capillary gas chromatography using a programmed-temperature vaporizing injector in the on-column or solvent-vent injection mode [J].
Bosboom, JC ;
Janssen, HG ;
Mol, HGJ ;
Cramers, CA .
JOURNAL OF CHROMATOGRAPHY A, 1996, 724 (1-2) :384-391
[4]   Comprehensive two-dimensional gas chromatography:: a powerful and versatile analytical tool [J].
Dallüge, J ;
Beens, J ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :69-108
[5]   Characterisation of fatty acids in biological oil samples using comprehensive multidimensional gas chromatography [J].
de Geus, HJ ;
Aidos, I ;
de Boer, J ;
Luten, JB ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) :95-103
[6]   DIRECT GAS-CHROMATOGRAPHIC ANALYSIS OF THE UNSAPONIFIABLE FRACTION OF DIFFERENT OILS WITH A POLAR CAPILLARY COLUMN [J].
FREGA, N ;
BOCCI, F ;
LERCKER, G .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1992, 69 (05) :447-450
[7]  
Fritsche J, 1999, FETT-LIPID, V101, P272, DOI 10.1002/(SICI)1521-4133(199908)101:8<272::AID-LIPI272>3.3.CO
[8]  
2-N
[9]  
FRITSCHE J, 1998, LIPID TECHNOL NEWSLE, V4, P115
[10]   CAPILLARY GC OF TRIGLYCERIDES IN FATS AND OILS USING A HIGH-TEMPERATURE PHENYLMETHYLSILICONE STATIONARY PHASE .2. THE ANALYSIS OF CHOCOLATE FATS [J].
GEERAERT, E ;
SANDRA, P .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1987, 64 (01) :100-105