Efficacy of antiadhesive, antibiotic and antiseptic coatings in preventing catheter-related infections: Review

被引:64
作者
Donelli, G [1 ]
Francolini, I [1 ]
机构
[1] Ist Super Sanita, Ultrastrutture Lab, I-00161 Rome, Italy
关键词
central venous catheters; anti-adhesive coatings; antibiotics; antiseptics; catheter-related infections;
D O I
10.1179/joc.2001.13.6.595
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In recent years, central venous catheters (CVCs) are increasingly used in clinical practice. However, complications such as local or systemic infections are frequent for both temporary and indwelling vascular catheters. Annually, in the United States of America there are more than 200,000 cases of nosocomial bloodstream infections (BSIs), of which 90% are related to the use of an intravascular device. These infections are associated with increased morbidity and mortality, prolonged hospitalization and growing medical costs. Technological treatments of polymer surfaces including coating the catheter with antimicrobial substances may be promising tools for prevention of catheter-associated infections. A large number of surface-treated central venous catheters are now commercially available. In this paper the features and the clinical efficacy of different antimicrobial coatings are reviewed.
引用
收藏
页码:595 / 606
页数:12
相关论文
共 88 条
[31]   BIOMATERIAL-CENTERED INFECTION - MICROBIAL ADHESION VERSUS TISSUE INTEGRATION [J].
GRISTINA, AG .
SCIENCE, 1987, 237 (4822) :1588-1595
[32]   ADHESIVE COLONIZATION OF BIOMATERIALS AND ANTIBIOTIC-RESISTANCE [J].
GRISTINA, AG ;
HOBGOOD, CD ;
WEBB, LX ;
MYRVIK, QN .
BIOMATERIALS, 1987, 8 (06) :423-426
[33]   A PROSPECTIVE, RANDOMIZED EVALUATION OF THE EFFECT OF SILVER IMPREGNATED SUBCUTANEOUS CUFFS FOR PREVENTING TUNNELED CHRONIC VENOUS ACCESS CATHETER INFECTIONS IN CANCER-PATIENTS [J].
GROEGER, JS ;
LUCAS, AB ;
COIT, D ;
LAQUAGLIA, M ;
BROWN, AE ;
TURNBULL, A ;
EXELBY, P .
ANNALS OF SURGERY, 1993, 218 (02) :206-210
[34]  
GUIDA SH, 1989, P GEN M AM SOC MICR
[35]  
Hannan M, 1999, ANAESTHESIA, V54, P868
[36]   Influence of triple-lumen central venous catheters coated with chlorhexidine and silver sulfadiazine on the incidence of catheter-related bacteremia [J].
Heard, SO ;
Wagle, M ;
Vijayakumar, E ;
McLean, S ;
Brueggemann, A ;
Napolitano, LM ;
Edwards, LP ;
O'Connell, FM ;
Puyana, JC ;
Doern, GV .
ARCHIVES OF INTERNAL MEDICINE, 1998, 158 (01) :81-87
[37]   BACTERIAL ADHERENCE TO HYDROPHILIC POLYMER-COATED POLYURETHANE STENTS [J].
JANSEN, B ;
GOODMAN, LP ;
RUITEN, D .
GASTROINTESTINAL ENDOSCOPY, 1993, 39 (05) :670-673
[38]   INVITRO EFFICACY OF A CENTRAL VENOUS CATHETER (HYDROCATH) LOADED WITH TEICOPLANIN TO PREVENT BACTERIAL-COLONIZATION [J].
JANSEN, B ;
JANSEN, S ;
PETERS, G ;
PULVERER, G .
JOURNAL OF HOSPITAL INFECTION, 1992, 22 (02) :93-107
[39]   Reduced intravascular catheter-related infection by routine use of antibiotic-bonded catheters in a surgical intensive care unit [J].
Kamal, GD ;
Divishek, D ;
Kumar, GC ;
Porter, BR ;
Tatman, DJ ;
Adams, JR .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1998, 30 (03) :145-152
[40]   REDUCED INTRAVASCULAR CATHETER INFECTION BY ANTIBIOTIC BONDING - A PROSPECTIVE, RANDOMIZED, CONTROLLED TRIAL [J].
KAMAL, GD ;
PFALLER, MA ;
REMPE, LE ;
JEBSON, PJR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 265 (18) :2364-2368