Microfluidic platform for real-time signaling analysis of multiple single T cells in parallel

被引:112
作者
Faley, Shannon [1 ,2 ]
Seale, Kevin [1 ,2 ]
Hughey, Jacob [1 ,2 ]
Schaffer, David K. [1 ,2 ]
VanCornpernolle, Scott [3 ]
McKinney, Brett [4 ]
Baudenbacher, Franz [1 ,2 ]
Unutmaz, Derya [5 ]
Wikswo, John P. [1 ,2 ,6 ,7 ]
机构
[1] Vanderbilt Univ, Vanderbilt Inst Integrat Biosyst Res & Educ, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Sch Med, Dept Immunol, Nashville, TN 37232 USA
[4] Univ Alabama Birmingham, Sch Med, Dept Genet, Birmingham, AL 35294 USA
[5] NYU, Sch Med, Dept Microbiol, New York, NY 10016 USA
[6] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37235 USA
[7] Vanderbilt Univ, Sch Med, Dept Mol Physiol & Biophys, Nashville, TN 37232 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1039/b719799c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Deciphering the signaling pathways that govern stimulation of naive CD4+ T helper cells by antigen-presenting cells via formation of the immunological synapse is key to a fundamental understanding of the progression of successful adaptive immune response. The study of T cell-APC interactions in vitro is challenging, however, due to the difficulty of tracking individual, non-adherent cell pairs over time. Studying single cell dynamics over time reveals rare, but critical, signaling events that might be averaged out in bulk experiments, but these less common events are undoubtedly important for an integrated understanding of a cellular response to its microenvironment. We describe a novel application of microfluidic technology that overcomes many limitations of conventional cell culture and enables the study of hundreds of passively sequestered hematopoietic cells for extended periods of time. This microfluidic cell trap device consists of 440 18 mu m x 18 mu m x 10 mu m PDMS, bucket-like structures opposing the direction of flow which serve as corrals for cells as they pass through the cell trap region. Cell viability analysis revealed that more than 70% of naive CD4+ T cells (T-N), held in place using only hydrodynamic forces, subsequently remain viable for 24 hours. Cytosolic calcium transients were successfully induced in T-N cells following introduction of chemical, antibody, or cellular forms of stimulation. Statistical analysis of T-N cells from a single stimulation experiment reveals the power of this platform to distinguish different calcium response patterns, an ability that might be utilized to characterize T cell signaling states in a given population. Finally, we investigate in real time contact- and non-contact-based interactions between primary T cells and dendritic cells, two main participants in the formation of the immunological synapse. Utilizing the microfluidic traps in a daisy-chain configuration allowed us to observe calcium transients in T-N cells exposed only to media conditioned by secretions of lipopolysaccharide-matured dendritic cells, an event which is easily missed in conventional cell culture where large media-to-cell ratios dilute cellular products. Further investigation into this intercellular signaling event indicated that LPS-matured dendritic cells, in the absence of antigenic stimulation, secrete chemical signals that induce calcium transients in T-N cells. While the stimulating factor(s) produced by the mature dendritic cells remains to be identified, this report illustrates the utility of these microfluidic cell traps for analyzing arrays of individual suspension cells over time and probing both contact-based and intercellular signaling events between one or more cell populations.
引用
收藏
页码:1700 / 1712
页数:13
相关论文
共 51 条
[31]   Human in vivo-activated CD45R0+ CD4+ T cells are susceptible to spontaneous apoptosis that can be inhibited by the chemokine CXCL12 and IL-2,-6,-7, and-15 [J].
Pajusto, M ;
Ihalainen, N ;
Pelkonen, J ;
Tarkkanen, J ;
Mattila, PS .
EUROPEAN JOURNAL OF IMMUNOLOGY, 2004, 34 (10) :2771-2780
[32]   DETECTION OF CELL-AFFECTING AGENTS WITH A SILICON BIOSENSOR [J].
PARCE, JW ;
OWICKI, JC ;
KERCSO, KM ;
SIGAL, GB ;
WADA, HG ;
MUIR, VC ;
BOUSSE, LJ ;
ROSS, KL ;
SIKIC, BI ;
MCCONNELL, HM .
SCIENCE, 1989, 246 (4927) :243-247
[33]   NanoLiterBioReactor: Long-term mammalian cell culture at nanofabricated scale [J].
Prokop, A ;
Prokop, Z ;
Schaffer, D ;
Kozlov, E ;
Wikswo, J ;
Cliffel, D ;
Baudenbacher, F .
BIOMEDICAL MICRODEVICES, 2004, 6 (04) :325-339
[34]   IL-7 enhances the survival and maintains the size of naive T cells [J].
Rathmell, JC ;
Farkash, EA ;
Gao, W ;
Thompson, CB .
JOURNAL OF IMMUNOLOGY, 2001, 167 (12) :6869-6876
[35]   Causal protein-signaling networks derived from multiparameter single-cell data [J].
Sachs, K ;
Perez, O ;
Pe'er, D ;
Lauffenburger, DA ;
Nolan, GP .
SCIENCE, 2005, 308 (5721) :523-529
[36]   Culturing of human peripheral blood cells reveals unsuspected lymphocyte responses relevant to HIV disease [J].
Sahaf, Bita ;
Atkuri, Kondala ;
Heydari, Kartoosh ;
Malipatlolla, Meena ;
Rappaport, Jay ;
Regulier, Emmanuel ;
Herzenberg, Leonard A. ;
Herzenberg, Leonore A. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2008, 105 (13) :5111-5116
[37]  
SEALE KT, 2008, BIOMED MICRODE UNPUB
[38]   Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies [J].
Sia, SK ;
Whitesides, GM .
ELECTROPHORESIS, 2003, 24 (21) :3563-3576
[39]   INTERLEUKIN-2 - INCEPTION, IMPACT, AND IMPLICATIONS [J].
SMITH, KA .
SCIENCE, 1988, 240 (4856) :1169-1176
[40]   User-friendly semiautomated assembly of accurate image mosaics in microscopy [J].
Thevenaz, Philippe ;
Unser, Michael .
MICROSCOPY RESEARCH AND TECHNIQUE, 2007, 70 (02) :135-146