Flow injection analysis with multiple on-line spectroscopic analysis (UV, IR, 1H-NMR and MS)

被引:15
作者
Lenz, E
Taylor, S
Collins, C
Wilson, ID
Louden, D
Handley, A
机构
[1] AstraZeneca Pharmaceut, Drug Metab & Pharmacokinet Dept, Macclesfield SK10 4TG, Cheshire, England
[2] LGC, Runcorn WA7 4QD, Cheshire, England
关键词
flow injection analysis; multiple hyphenation; spectroscopic characterisation;
D O I
10.1016/S0731-7085(01)00534-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Studies on the capabilities of flow injection analysis (FIA) combined with on-line characterisation of model compounds via a combination of diode array UV, H-1-NMR, FT-IR spectroscopy and mass spectrometry are described. Using this combination of spectrometers enabled the on-flow collection of UV, H-1-NMR, IR and MS for a range of model compounds. Samples were introduced into the system as solutions in deuterium oxide in concentrations ranging from 1.4 to 8.4 mg ml(-1). A sample volume of 100 mul was used for FIA at a flow rate of 1 ml min(-1). From these studies a practical working quantity of ca. 140 mug/sample of analyte was determined which provided characteristic spectra. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:191 / 200
页数:10
相关论文
共 17 条
[1]   The application of high performance liquid chromatography, coupled to nuclear magnetic resonance spectroscopy and mass spectrometry (HPLC-NMR-MS), to the characterisation of ibuprofen metabolites from human urine [J].
Clayton, E ;
Taylor, S ;
Wright, B ;
Wilson, ID .
CHROMATOGRAPHIA, 1998, 47 (5-6) :264-270
[2]  
Dear GJ, 1998, RAPID COMMUN MASS SP, V12, P2023, DOI 10.1002/(SICI)1097-0231(19981230)12:24<2023::AID-RCM431>3.0.CO
[3]  
2-6
[4]   High-performance liquid chromatography on-line coupled to high-field NMR and mass spectrometry for structure elucidation of constituents of Hypericum perforatum L. [J].
Hansen, SH ;
Jensen, AG ;
Cornett, C ;
Bjornsdottir, I ;
Taylor, S ;
Wright, B ;
Wilson, ID .
ANALYTICAL CHEMISTRY, 1999, 71 (22) :5235-5241
[5]  
Holt RM, 1997, J MASS SPECTROM, V32, P64, DOI 10.1002/(SICI)1096-9888(199701)32:1<64::AID-JMS450>3.0.CO
[6]  
2-7
[7]   Reversed-phase high-performance liquid chromatography combined with on-line UV diode array, FT infrared, and 1H nuclear magnetic resonance spectroscopy and time-of-flight mass spectrometry:: Application to a mixture of nonsteroidal antiinflammatory drugs [J].
Louden, D ;
Handley, A ;
Taylor, S ;
Lenz, E ;
Miller, S ;
Wilson, ID ;
Sage, A .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3922-3926
[8]   Flow injection spectroscopic analysis of model drugs using on-line UV-diode array, FT-infrared and 1H-nuclear magnetic resonance spectroscopy and time-of-flight mass spectrometry [J].
Louden, D ;
Handley, A ;
Taylor, S ;
Lenz, E ;
Miller, S ;
Wilson, ID ;
Sage, A .
ANALYST, 2000, 125 (05) :927-931
[9]   Spectroscopic characterisation and identification of ecdysteroids using high-performance liquid chromatography combined with on-line UV-diode array, FT-infrared and 1H-nuclear magnetic resonance spectroscopy and time of flight mass spectrometry [J].
Louden, D ;
Handley, A ;
Taylor, S ;
Lenz, E ;
Miller, S ;
Wilson, ID ;
Sage, A ;
Lafont, R .
JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (02) :237-246
[10]   Size-exclusion chromatography with on-line ultraviolet, proton nuclear magnetic resonance and mass spectrometric detection and on-line collection for off-line Fourier transform infrared spectroscopy [J].
Ludlow, M ;
Louden, D ;
Handley, A ;
Taylor, S ;
Wright, B ;
Wilson, ID .
JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) :89-96