New joints for the Millennium: wear control in total replacement hip joints

被引:112
作者
Dowson, D [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
total replacement hip joints (THR); Millennium prostheses; friction; wear; lubrication;
D O I
10.1243/0954411011535939
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hip joint replacement is described as the greatest achievement in orthopaedic surgery in the twentieth century. The field has been dominated for some forty years by implants based upon metallic femoral heads and stems and polymeric acetabular cups. At the dawn of the new Millennium, many alternative materials and designs are now being proposed or evaluated. The reasons for these developments and the current contributions of engineering science and tribology to advances in hip replacement are discussed. Illustrations are presented of the significant changes being proposed or introduced. While the new designs of total hip replacements offer exciting engineering contributions to the future of joint replacement, the long-term benefits to patients will depend upon the biological response to the new devices.
引用
收藏
页码:335 / 358
页数:24
相关论文
共 109 条
[1]  
AMSTUTZ HC, 1996, CLIN ORTHOP S, V329, pS11
[2]  
[Anonymous], CLIN ORTHOPAEDICS
[3]  
[Anonymous], CLIN ORTHOP
[4]   LABORATORY WEAR TESTS AND CLINICAL OBSERVATIONS OF THE PENETRATION OF FEMORAL HEADS INTO ACETABULAR CUPS IN TOTAL REPLACEMENT HIP JOINTS .3. THE MEASUREMENT OF INTERNAL VOLUME CHANGES IN EXPLANTED CHARNLEY SOCKETS AFTER 2-16 YEARS INVIVO AND THE DETERMINATION OF WEAR FACTORS [J].
ATKINSON, JR ;
DOWSON, D ;
ISAAC, JH ;
WROBLEWSKI, BM .
WEAR, 1985, 104 (03) :225-244
[5]  
Auger D D, 1995, Proc Inst Mech Eng H, V209, P83, DOI 10.1243/PIME_PROC_1995_209_324_02
[6]  
AUGER DD, 1995, J ENG MED, V209, P72
[7]  
AUGER DD, 1990, P 16 LEEDS LYON S TR, P251
[8]   THE MCKEE-FARRAR HIP-ARTHROPLASTY - A LONG-TERM STUDY [J].
AUGUST, AC ;
ALDAM, CH ;
PYNSENT, PB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (04) :520-527
[9]   A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates [J].
Barbour, PSM ;
Stone, MH ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) :455-467
[10]   A comparative tribological study of the wear of composite cushion cups in a physiological hip joint simulator [J].
Bigsby, RJA ;
Auger, DD ;
Jin, ZM ;
Dowson, D ;
Hardaker, CS ;
Fisher, J .
JOURNAL OF BIOMECHANICS, 1998, 31 (04) :363-369