Laser Ablation Coupled to a Flowing Atmospheric Pressure Afterglow for Ambient Mass Spectral Imaging

被引:92
作者
Shelley, Jacob T. [1 ]
Ray, Steven J. [1 ]
Hieftje, Gary M. [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
关键词
D O I
10.1021/ac801594u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A plasma-based ambient desorption/ionization mass spectrometry (ADI-MS) source was used to perform molecular mass spectral imaging. A small amount of sample material was ablated by focusing 266 nm laser light onto a spot. The resulting aerosol was transferred by a nitrogen stream to the flowing afterglow of a helium atmospheric pressure glow discharge ionization source; the ionized sample material was analyzed by a Leco Unique time-of-flight mass spectrometer. Two-dimensional mass spectral images were generated by scanning the laser beam across a sample surface. The total analysis time for a 6 mm(2) surface, which is limited by the washout of the ablation chamber, was less than 30 min. With this technique, a spatial resolution of similar to 20 pin has been achieved. Additionally, the laser ablation configuration was used to obtain depth information of over 2 min with a resolution of similar to 40 pm. The combination of laser ablation with the flowing atmospheric pressure afterglow source was used to analyze several sample surfaces for a wide variety of analytes and with high sensitivity (LOD of 5 fmol for caffeine).
引用
收藏
页码:8308 / 8313
页数:6
相关论文
共 21 条
[11]   Atmospheric pressure molecular imaging by infrared MALDI mass spectrometry [J].
Li, Yue ;
Shrestha, Bindesh ;
Vertes, Akos .
ANALYTICAL CHEMISTRY, 2007, 79 (02) :523-532
[12]   High-spatial resolution mass spectrometric imaging of peptide and protein distributions on a surface [J].
Luxembourg, SL ;
Mize, TH ;
McDonnell, LA ;
Heeren, RMA .
ANALYTICAL CHEMISTRY, 2004, 76 (18) :5339-5344
[13]   Imaging mass spectrometry [J].
McDonnell, Liam A. ;
Heeren, Ron M. A. .
MASS SPECTROMETRY REVIEWS, 2007, 26 (04) :606-643
[14]   Development of a dielectric barrier discharge ion source for ambient mass spectrometry [J].
Na, Na ;
Zhao, Mengxia ;
Zhang, Sichun ;
Yang, Chengdui ;
Zhang, Xinrong .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (10) :1859-1862
[15]   Ambient molecular imaging and depth profiling of live tissue by infrared laser ablation electrospray ionization mass spectrometry [J].
Nemes, Peter ;
Barton, Alexis A. ;
Li, Yue ;
Vertes, Akos .
ANALYTICAL CHEMISTRY, 2008, 80 (12) :4575-4582
[16]   Laser ablation electrospray ionization for atmospheric pressure, in vivo, and imaging mass spectrometry [J].
Nemes, Peter ;
Vertes, Akos .
ANALYTICAL CHEMISTRY, 2007, 79 (21) :8098-8106
[17]   Surface analysis under ambient conditions using plasma-assisted desorption/ionization mass spectrometry [J].
Ratcliffe, Lucy V. ;
Rutten, Frank J. M. ;
Barrett, David A. ;
Whitmore, Terry ;
Seymour, David ;
Greenwood, Claire ;
Aranda-Gonzalvo, Yolanda ;
Robinson, Steven ;
McCoustra, Martin .
ANALYTICAL CHEMISTRY, 2007, 79 (16) :6094-6101
[18]   Mass spectrometry sampling under ambient conditions with desorption electrospray ionization [J].
Takáts, Z ;
Wiseman, JM ;
Gologan, B ;
Cooks, RG .
SCIENCE, 2004, 306 (5695) :471-473
[19]   Ambient mass spectrometry using desorption electrospray ionization (DESI):: instrumentation, mechanisms and applications in forensics, chemistry, and biology [J].
Takáts, Z ;
Wiseman, JM ;
Cooks, RG .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (10) :1261-1275
[20]   Droplet dynamics and ionization mechanisms in desorption electrospray ionization mass spectrometry [J].
Venter, Andre ;
Sojka, Paul E. ;
Cooks, R. Graham .
ANALYTICAL CHEMISTRY, 2006, 78 (24) :8549-8555