Intravascular ultrasound image segmentation:: A three-dimensional fast-marching method based on gray level distributions

被引:103
作者
Cardinal, MHR
Meunier, J
Soulez, G
Maurice, RL
Therasse, É
Cloutier, G
机构
[1] Univ Montreal Hosp, Res Ctr, Lab Biorheol & Med Ultrason, Montreal, PQ H2L 2W5, Canada
[2] Univ Montreal, Dept Informat & Rech Operat, Montreal, PQ H3A 2B2, Canada
[3] Univ Montreal Hosp, Dept Radiol, Montreal, PQ H2L 2W5, Canada
关键词
fast-marching; IVUS; probability density function; segmentation; 3-D imaging;
D O I
10.1109/TMI.2006.872142
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Intravascular ultrasound (IVUS) is a catheter based medical imaging technique particularly useful for studying atherosclerotic disease. It produces cross-sectional images of blood vessels that provide quantitative assessment of the vascular wall, information about the nature of atherosclerotic lesions as well as plaque shape and size. Automatic processing of large IVUS data sets represents an important challenge due to ultrasound speckle, catheter artifacts or calcification shadows. A new three-dimensional (3-D) IVUS segmentation model, that is based on the fast-marching method and uses gray level probability density functions (PDFs) of the vessel wall structures, was developed. The gray level distribution of the whole IVUS pullback was modeled with a mixture of Rayleigh PDFs. With multiple interface fast-marching segmentation, the lumen, intima plus plaque structure, and media layers of the vessel wall were computed simultaneously. The PDF-based fast-marching was applied to 9 in vivo IVUS pullbacks of superficial femoral arteries and to a simulated IVUS pullback. Accurate results were obtained on simulated data with average point to point distances between detected vessel wall borders and ground truth <0.072 mm. On in vivo IVUS, a good overall performance was obtained with average distance between segmentation results and manually traced contours <0.16 mm. Moreover, the worst point to point variation between detected and manually traced contours stayed low with Hausdorff distances <0.40 mm, indicating a good performance in regions lacking information or containing artifacts. In conclusion, segmentation results demonstrated the potential of gray level PDF and fast-marching methods in 3-D IVUS image processing.
引用
收藏
页码:590 / 601
页数:12
相关论文
共 37 条
[1]   Multi-agent segmentation of IVUS images [J].
Bovenkamp, EGP ;
Dijkstra, J ;
Bosch, JG ;
Reiber, JHC .
PATTERN RECOGNITION, 2004, 37 (04) :647-663
[2]   Fully automatic luminal contour segmentation in intracoronary ultrasound imaging - A statistical approach [J].
Brusseau, E ;
de Korte, CL ;
Mastik, F ;
Schaar, J ;
van der Steen, AFW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) :554-566
[3]   SPECKLE IN ULTRASOUND B-MODE SCANS [J].
BURCKHARDT, CB .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (01) :1-6
[4]  
Cardinal MHR, 2003, LECT NOTES COMPUT SC, V2879, P432
[5]   A methodology for evaluation of boundary detection algorithms on medical images [J].
Chalana, V ;
Kim, YM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (05) :642-652
[6]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[7]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[8]   Statistics of the log-compressed echo envelope [J].
Dutt, V ;
Greenleaf, JF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 99 (06) :3817-3825
[9]   The Rician inverse Gaussian distribution: A new model for non-Rayleigh signal amplitude statistics [J].
Eltoft, T .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2005, 14 (11) :1722-1735
[10]   COMPENSATORY ENLARGEMENT OF HUMAN ATHEROSCLEROTIC CORONARY-ARTERIES [J].
GLAGOV, S ;
WEISENBERG, E ;
ZARINS, CK ;
STANKUNAVICIUS, R ;
KOLETTIS, GJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (22) :1371-1375