A biomechanical comparison of three anterior thoracolumbar implants after corpectomy: are two screws better than one?

被引:16
作者
Chou, D
Larios, AE
Chamberlain, RH
Fifield, MS
Hartl, R
Dickman, CA
Sonntag, VKH
Crawford, NR
机构
[1] St Josephs Hosp, Barrow Neurol Inst, Div Neurol Surg, Phoenix, AZ 85013 USA
[2] St Josephs Hosp, Barrow Neurol Inst, Spinal Biomech Lab, Phoenix, AZ 85013 USA
[3] Univ Calif San Francisco, Dept Neurosurg, San Francisco, CA 94143 USA
关键词
biomechanics; thoracic spine; anterior fixation; corpectomy;
D O I
10.3171/spi.2006.4.3.213
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. A flexibility experiment using human cadaveric thoracic spine specimens was performed to determine biomechanical differences among thoracolumbar two-screw plate, single-screw plate, and dual-rod systems. A secondary goal was to investigate differences in the ability of the systems to stabilize the spine after a one- or two-level corpectomy. Methods. The authors evaluated 21 cadaveric spines implanted with a titanium mesh cage and three types of anterior thoracolumbar supplementary instrumentation after one-level thoracic corpectomies. Pure moments were applied quasistatically while three-dimensional motion was measured optoelectronically. The lax zone, stiff zone, and range of motion (ROM) were measured during flexion, extension, left and right lateral bending, and left and right axial rotation. Corpectomies were expanded to two levels, and testing was repeated with longer hardware. Biomechanical testing showed that the single-bolt plate system was no different from the dual-rod system with two screws in limiting ROM. The single-bolt plate system performed slightly better than the two-screw plate system. Across the same two levels, there was an average of 19% more motion after a two-level corpectomy than after a one-level corpectomy. In general, however, the difference across the different loading modes was insignificant. Conclusions. Biomechanically, the single-screw plate system is equivalent to a two-screw dual-rod and a two-screw plate system. All three systems performed similarly in stabilizing the spine after one- or two-level corpectomies.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 12 条
[1]
A new technique for determining 3-D joint angles: the tilt/twist method [J].
Crawford, NR ;
Yamaguchi, GT ;
Dickman, CA .
CLINICAL BIOMECHANICS, 1999, 14 (03) :153-165
[2]
AN APPARATUS FOR APPLYING PURE NONCONSTRAINING MOMENTS TO SPINE SEGMENTS IN-VITRO [J].
CRAWFORD, NR ;
BRANTLEY, AGU ;
DICKMAN, CA ;
KOENEMAN, EJ .
SPINE, 1995, 20 (19) :2097-2100
[3]
Construction of local vertebral coordinate systems using a digitizing probe - Technical note [J].
Crawford, NR ;
Dickman, CA .
SPINE, 1997, 22 (05) :559-563
[4]
Crawford NR, 1998, J SPINAL DISORD, V11, P416
[5]
In vitro biomechanical analysis of three anterior thoracolumbar implants [J].
Hitchon, PW ;
Goel, VK ;
Rogge, TN ;
Torner, JC ;
Dooris, AP ;
Drake, JS ;
Yang, SJ ;
Totoribe, K .
JOURNAL OF NEUROSURGERY, 2000, 93 (02) :252-258
[6]
A biomechanical analysis of triangulation of anterior vertebral double-screw fixation [J].
Huang, TJ ;
Hsu, RWW ;
Tai, CL ;
Chen, WP .
CLINICAL BIOMECHANICS, 2003, 18 (06) :S40-S45
[7]
Biomechanical analysis of anterior versus circumferential spinal reconstruction for various anatomic stages of tumor lesions [J].
Kanayama, M ;
Ng, JTW ;
Cunningham, BW ;
Abumi, K ;
Kaneda, K ;
McAfee, PC .
SPINE, 1999, 24 (05) :445-450
[8]
New anterior instrumentation for the management of thoracolumbar and lumbar scoliosis - Application of the Kaneda two-rod system [J].
Kaneda, K ;
Shono, Y ;
Satoh, S ;
Abumi, K .
SPINE, 1996, 21 (10) :1250-1261
[9]
Central and juxta-endplate vertebral body screw placement - A biomechanical analysis in a human cadaveric model [J].
Lowe, T ;
O'Brien, M ;
Smith, D ;
Fitzgerald, D ;
Vraney, R ;
Eule, J ;
Alongi, P .
SPINE, 2002, 27 (04) :369-373
[10]
BIOMECHANICAL TIME-TOLERANCE OF FRESH CADAVERIC HUMAN SPINE SPECIMENS [J].
PANJABI, MM ;
KRAG, M ;
SUMMERS, D ;
VIDEMAN, T .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (03) :292-300