RR interval variability in irregular monomorphic ventricular tachycardia and atrial fibrillation

被引:40
作者
GarciaAlberola, A
YliMayry, S
Block, M
Haverkamp, W
MartinezRubio, A
Kottkamp, H
Breithardt, G
Borggrefe, M
机构
[1] HOSP WESTFAL WILHELMS UNIV MUNSTER,DEPT CARDIOL & ANGIOL,MUNSTER,GERMANY
[2] HOSP WESTFAL WILHELMS UNIV MUNSTER,INST RES ARTERIOSCLEROSIS,MUNSTER,GERMANY
基金
英国医学研究理事会;
关键词
tachycardia; fibrillation; implantable; cardioverter-defibrillator;
D O I
10.1161/01.CIR.93.2.295
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Algorithms to reject irregular tachyarrhythmias are available in implantable cardioverter-defibrillator devices to discriminate ventricular tachycardia (VT) from atrial fibrillation (AF). The hazard of underdetection of irregular monomorphic VTs using these algorithms has not yet been fully evaluated. The purpose of this study was to determine the ability of a commonly used stability algorithm to reject AF and to correctly detect VT with a high RR interval variability. Methods and Results The electrophysiological studies from 232 patients with induced monomorphic VT (cycle length >250 ms) and 21 with AF were reviewed. A preliminary analysis was performed to classify the VT episodes in irregular (successive RR differences >20 ms after 4 seconds from onset) or regular (otherwise). Three study groups were defined: group 1 (27 patients with irregular VT), group 2 (22 randomly selected patients with regular VT), and group 3 (21 patients with AE). A computer program analyzed the first 50 RR intervals of the induced VT (AF), resetting a VT counter if the interval was greater than a tachycardia detection interval (TDI) or if its absolute difference with the preceding three beats exceeded a programmed stability value (STAB). The VT was detected when the VT counter reached a preset number of intervals (NIDs). Different combinations of TDI, STAB, and NID were analyzed. All VTs in group 2 were correctly detected. In contrast, up to 10 VTs from group 1 were not detected when high NIDs and low STAB parameters were programmed. With usual values (10 to 16 beats and 50 to 60 ms, respectively), only 1 to 2 VTs remained undetected, but 20% to 50% had a detection delay >8 seconds. Undetected VTs were significantly slower than early detected VTs for most STAB and NID combinations. With usual stability and NID values, 10% to 20% of episodes of AF were inappropriately detected. Changes in TDI had a small impact on sensitivity and specificity when currently used values for stability were programmed. Conclusions An implantable cardioverter-defibrillator tachycardia detection algorithm with a stability criterion of 50 to 60 ms and 12 to 14 RR intervals is able to detect over 90% of monomorphic irregular VTs. Nevertheless, significant VT detection delays may arise, and inappropriate detection of AF cannot be totally prevented.
引用
收藏
页码:295 / 300
页数:6
相关论文
共 31 条
[1]   CLINICAL-EXPERIENCE WITH A TIERED-THERAPY, MULTIPROGRAMMABLE ANTIARRHYTHMIA DEVICE [J].
BARDY, GH ;
TROUTMAN, C ;
POOLE, JE ;
KUDENCHUK, PJ ;
DOLACK, GL ;
JOHNSON, G ;
HOFER, B .
CIRCULATION, 1992, 85 (05) :1689-1698
[2]   IMPLANTABLE TRANSVENOUS CARDIOVERTER-DEFIBRILLATORS [J].
BARDY, GH ;
HOFER, B ;
JOHNSON, G ;
KUDENCHUK, PJ ;
POOLE, JE ;
DOLACK, GL ;
GLEVA, M ;
MITCHELL, R ;
KELSO, D .
CIRCULATION, 1993, 87 (04) :1152-1168
[3]   SPONTANEOUS COMPARED WITH INDUCED ONSET OF SUSTAINED VENTRICULAR-TACHYCARDIA [J].
BERGER, MD ;
WAXMAN, HL ;
BUXTON, AE ;
MARCHLINSKI, FE ;
JOSEPHSON, ME .
CIRCULATION, 1988, 78 (04) :885-892
[4]   HOLTER DOCUMENTED SUDDEN-DEATH IN A PATIENT WITH AN IMPLANTED DEFIBRILLATOR [J].
BIRGERSDOTTERGREEN, U ;
ROSENQVIST, M ;
LINDEMANS, FW ;
RYDEN, L ;
RADEGRAN, K .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (07) :1008-1014
[5]   PREDICTIVE VALUE OF ELECTROPHYSIOLOGIC TESTING IN THE TREATMENT OF DRUG-REFRACTORY VENTRICULAR ARRHYTHMIAS WITH AMIODARONE [J].
BORGGREFE, M ;
BREITHARDT, G .
EUROPEAN HEART JOURNAL, 1986, 7 (09) :735-742
[6]   REAPPRAISAL OF CRITERIA FOR ASSESSING DRUG EFFICACY IN PATIENTS WITH VENTRICULAR TACHYARRHYTHMIAS - COMPLETE VERSUS PARTIAL SUPPRESSION OF INDUCIBLE ARRHYTHMIAS [J].
BORGGREFE, M ;
TRAMPISCH, HJ ;
BREITHARDT, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (01) :140-149
[7]   AUTOCORRELATION OF VENTRICULAR RESPONSE IN ATRIAL FIBRILLATION [J].
BRAUNSTEIN, J ;
FRANKE, EK .
CIRCULATION RESEARCH, 1961, 9 (02) :300-&
[8]   IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - VENTRITEX(R) CADENCE(R) [J].
FAIN, ES ;
WINKLE, RA .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1993, 4 (02) :211-223
[9]  
FROMER M, 1987, PACE, V10, P593
[10]  
FROMER M, 1993, CARDIAC MAPPING, P507