Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia

被引:81
作者
Zadok, D [1 ]
Tran, DB [1 ]
Twa, M [1 ]
Carpenter, M [1 ]
Schanzlin, DJ [1 ]
机构
[1] Univ Calif San Diego, Shiley Eye Ctr, La Jolla, CA 92093 USA
关键词
D O I
10.1016/S0886-3350(99)00202-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the reliability of intraocular pressure (IOP) measurement by Goldmann applanation tonometry (GAT) versus pneumotonometry in patients after laser in situ keratomileusis (LASIK) for myopia. Setting: Shiley Eye Center, University of California San Diego, La Jolla, California, USA. Methods: in this prospective study, 31 eyes of 17 patients were evaluated before and 1 month after having LASIK for myopia. A masked observer measured preoperative and postoperative IOP by GAT centrally and by pneumotonometry at the center and the periphery of the cornea. Central corneal thickness and curvature were evaluated. Results: Preoperative IOP showed a good correlation between GAT and pneumotonometry values (r = 0.82). Mean postoperative IOP by GAT was lower by 3.8 mm Hg +/- 2.2 (SD) (26.3% +/- 15.2%) than by pneumotonometry: 2.3 +/- 2.8 mm Hg (15.4% +/- 10.7%) (P = .01). There were no statistically significant differences in central IOP versus peripheral IOP measured by pneumotonometry (P = .4). Regression analysis showed no statistically significant differences in IOP as a function of change in corneal thickness or change in corneal curvature with either device. Conclusion: Postoperatively, there was a decrease in IOP measured by central GAT that was statistically significant. Differences in pneumotonometry were less substantial, with greater reliability of pneumotonometry than GAT after LASIK. (C) 1999 ASCRS and ESCRS.
引用
收藏
页码:1344 / 1348
页数:5
相关论文
共 14 条
[1]   Ocular hypertension and central corneal thickness [J].
Argus, WA .
OPHTHALMOLOGY, 1995, 102 (12) :1810-1812
[2]   Reduction in intraocular pressure after excimer laser photorefractive keratectomy - Correlation with pretreatment myopia [J].
Chatterjee, A ;
Shah, S ;
Bessant, DA ;
Naroo, SA ;
Doyle, SJ .
OPHTHALMOLOGY, 1997, 104 (03) :355-359
[3]  
EHLERS N, 1974, ACTA OPHTHALMOL, V52, P740
[4]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[5]   Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis [J].
Emara, B ;
Probst, LE ;
Tingey, DP ;
Kennedy, DW ;
Willms, LJ ;
Machat, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (10) :1320-1325
[6]  
Kohlhaas M, 1995, EUR J IMPLANT REFRAC, V7, P84
[7]   The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer [J].
Mardelli, PG ;
Piebenga, LW ;
Whitacre, MM ;
Siegmund, KD .
OPHTHALMOLOGY, 1997, 104 (06) :945-948
[8]   CORNEAL CURVATURE IN APPLANATION TONOMETRY [J].
MARK, HH .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1973, 76 (02) :223-224
[9]   INTRAOCULAR-PRESSURE MEASUREMENT AFTER PENETRATING KERATOPLASTY - MINIFIED GOLDMANN APPLANATION TONOMETER, PNEUMATONOMETER, AND TONO-PEN VERSUS MANOMETRY [J].
MENAGE, MJ ;
KAUFMAN, PL ;
CROFT, MA ;
LANDAY, SP .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1994, 78 (09) :671-676
[10]  
MENDELSOHN AD, 1987, CORNEA, V6, P219