Daily targeting of intrahepatic tumors for radiotherapy

被引:82
作者
Balter, JM [1 ]
Brock, KK [1 ]
Litzenberg, DW [1 ]
McShan, DL [1 ]
Lawrence, TS [1 ]
Ten Haken, R [1 ]
McGinn, CJ [1 ]
Lam, KL [1 ]
Dawson, LA [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 52卷 / 01期
关键词
breathing movement; on-line setup; active breathing control;
D O I
10.1016/S0360-3016(01)01815-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: A system has been developed for daily targeting of intrahepatic tumors using a combination of ventilatory immobilization, in-room diagnostic imaging, and on-line setup adjustment. By reducing geometric position uncertainty, as well as organ movement, this system permits reduction of margins and thus potentially higher treatment doses. This paper reports our initial experience treating 8 patients with focal liver tumors using this system. Methods and Materials: The system includes diagnostic X-ray tubes mounted on the wall and ceiling of a treatment room, an active matrix flat panel imager, in-room control for image acquisition and setup adjustment, and a ventilatory immobilization system via active breathing control (ABC). Eight patients participated in the study, two using an early prototype ABC unit, and the remaining six with a commercial ABC system and improved setup measurement tools. Treatment margins were reduced, and dose consequently increased because of increased confidence in target position under this protocol. After daily setup via skin marks, orthogonal radiographs were acquired at suspended ventilation. The images were aligned to the CT model using the diaphragm for inferior-superior (IS) alignment, and the skeleton for left-right (LR) and anterior-posterior (AP) alignment. Adjustments were made for positioning errors greater than a threshold (3 or 5 mm). After treatment, retrospective analysis determined the final setup accuracy, as well as the error in initial setup measurement performed before setup adjustment. Results: Two hundred sixty-two treatment fractions were delivered on eight patients, with 171 treatments requiring repositioning. Typical treatment times were 25-30 min. Patients were able to tolerate ABC throughout the course of treatment. Breath holds up to 35 s long were used for treatment. The use of on-line imaging and setup adjustment reduced setup errors (sigma) from 4.0 mm (LR), 6.7 mm (IS), and 3.8 mm (AP) to 2.1 mm (LR), 3.5 mm (IS), and 2.3 mm (AP). Prescribed doses were increased using this system by an average of 5 Gy. Conclusions: Daily targeting of intrahepatic targets has been demonstrated to be feasible. The potential for reduction in treatment margin and consequential safe dose escalation has been demonstrated, while maintaining reasonable treatment delivery times. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:266 / 271
页数:6
相关论文
共 17 条
[1]   ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS [J].
BALTER, JM ;
CHEN, GTY ;
PELIZZARI, CA ;
KRISHNASAMY, S ;
RUBIN, S ;
VIJAYAKUMAR, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (01) :137-143
[2]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[3]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[4]   STEREOTAXIC HIGH-DOSE FRACTION RADIATION-THERAPY OF EXTRACRANIAL TUMORS USING AN ACCELERATOR - CLINICAL-EXPERIENCE OF THE FIRST 31 PATIENTS [J].
BLOMGREN, H ;
LAX, I ;
NASLUND, I ;
SVANSTROM, R .
ACTA ONCOLOGICA, 1995, 34 (06) :861-870
[5]   Respiration gated radiotherapy treatment: A technical study [J].
Kubo, HD ;
Hill, BC .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01) :83-91
[6]  
LITZENBERG D, IN PRESS P ICCR
[7]   A method for incorporating organ motion due to breathing into 3D dose calculations [J].
Lujan, AE ;
Larsen, EW ;
Balter, JM ;
Ten Haken, RK .
MEDICAL PHYSICS, 1999, 26 (05) :715-720
[8]   Quantization of setup uncertainties in 3-D dose calculations [J].
Lujan, AE ;
Ten Haken, RK ;
Larsen, EW ;
Balter, JM .
MEDICAL PHYSICS, 1999, 26 (11) :2397-2402
[9]  
MAGERAS G, 2000, MED PHYS, V27, P1419
[10]  
MURPHY M, IN PRESS COMPUTER AI