Determination of total nitrogen in food by flow injection analysis (FIA) with a potentiometric differential detection system

被引:12
作者
Lima, JLFC [1 ]
Montenegro, MCBSM [1 ]
Pinto, APMMO [1 ]
机构
[1] Fac Farm, CEQUP, Dept Quim Fis, P-4050 Porto, Portugal
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1999年 / 364卷 / 04期
关键词
D O I
10.1007/s002160051348
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection set-up based on potentiometric detection and gas diffusion device for the determination of total nitrogen in food is described. The detection system consisted of two ammonium-sensitive electrodes placed sequentially and each alternately operating as reference electrode. Tubular electrodes without an inner reference solution were prepared with a PVC membrane composed of nonactin in Tris (2-ethylhexyl) phosphate and potassium tetrakis (4-chlorophenyl) berate to reduce the membrane resistance. The food sample digests were inserted into the system, and the ammonium present was converted into ammonia gas. The gas diffused through a gas-permeable membrane to a buffer acceptor stream with a pH that ensured transformation to the ammonium cation, which was potentiometrically detected. Good agreement between FIA results and those provided by the reference procedure was obtained, with relative deviation errors below 5%. Using the proposed system, low reagent consumption is possible, a sampling rate of about 30 samples/h was achieved, as well as a good reproducibility for consecutive injections of the same sample (variation coefficient < 2%).
引用
收藏
页码:353 / 357
页数:5
相关论文
共 15 条
[1]   FLOW-THROUGH TUBULAR PVC MATRIX MEMBRANE-ELECTRODE WITHOUT INNER REFERENCE SOLUTION FOR FLOW-INJECTION ANALYSIS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
PAULIS, JM ;
LIMA, JLFC ;
MACHADO, AASC .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :147-152
[2]   FLOW-INJECTION SYSTEM FOR ONLINE POTENTIOMETRIC MONITORING OF AMMONIA IN FRESH-WATER STREAMS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
MARTINEZFABREGAS, E .
ANALYST, 1989, 114 (11) :1443-1447
[3]  
ALEGRET S, 1987, QUIM ANAL, V6, P278
[4]   FLOW-INJECTION ANALYSIS OF HIGH CHLORIDE LEVELS IN ELECTROPLATING BATHS USING ONLINE DIALYSIS AND POTENTIOMETRIC DETECTION [J].
ARAUJO, AN ;
ETXEBARRIA, MB ;
LIMA, JLFC ;
MONTENEGRO, MCBSM ;
OLMOS, RP .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (07) :614-617
[5]  
BUHRER T, 1988, PFLUG ARCH EUR J PHY, V412, P359
[6]   Potentiometric determination of total nitrogen in soils by flow injection analysis with a gas-diffusion unit [J].
Ferreira, AMR ;
Lima, JLFC ;
Rangel, AOSS .
AUSTRALIAN JOURNAL OF SOIL RESEARCH, 1996, 34 (04) :503-510
[7]  
Helrich K., 1990, ASS OFFICIAL ANAL CH
[8]   DETERMINATION OF AMMONIA IN LOW CONCENTRATIONS WITH NESSLERS REAGENT BY FLOW INJECTION ANALYSIS [J].
KRUG, FJ ;
RUZICKA, J ;
HANSEN, EH .
ANALYST, 1979, 104 (1234) :47-54
[9]   FLOW-INJECTION DETERMINATION OF AMMONIA IN KJELDAHL DIGESTS BY GAS-DIFFUSION AND CONDUCTOMETRY [J].
PASQUINI, C ;
DEFARIA, LC .
ANALYTICA CHIMICA ACTA, 1987, 193 :19-27
[10]  
SCHOLER RP, 1970, CHIMIA, V24, P372