Single-pass volumetric bidirectional blood flow imaging spectral domain optical coherence tomography using a modified Hilbert transform

被引:97
作者
Tao, Yuankai K. [1 ]
Davis, Anjul M. [1 ]
Izatt, Joseph A. [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
来源
OPTICS EXPRESS | 2008年 / 16卷 / 16期
关键词
D O I
10.1364/OE.16.012350
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate in vivo volumetric bidirectional blood flow imaging in animal models using single-pass flow imaging spectral domain optical coherence tomography. This technique uses a modified Hilbert transform algorithm to separate moving and non-moving scatterers within a depth. The resulting reconstructed image maps the components of moving scatterers flowing into and out of the imaging axis onto opposite image half-planes, enabling volumetric bidirectional flow mapping without manual segmentation. (C) 2008 Optical Society of America.
引用
收藏
页码:12350 / 12361
页数:12
相关论文
共 29 条
[1]   Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography [J].
An, Lin ;
Wang, Ruikang K. .
OPTICS LETTERS, 2007, 32 (23) :3423-3425
[2]   Resonant Doppler flow imaging and optical vivisection of retinal blood vessels [J].
Bachmann, Adrian H. ;
Villiger, Martin L. ;
Blatter, Cedric ;
Lasser, Theo ;
Leitgeb, Rainer A. .
OPTICS EXPRESS, 2007, 15 (02) :408-422
[3]   Heterodyne Fourier domain optical coherence tomography for full range probing with high axial resolution [J].
Bachmann, AH ;
Leitgeb, RA ;
Lasser, T .
OPTICS EXPRESS, 2006, 14 (04) :1487-1496
[4]   Full range complex spectral domain optical coherence tomography without additional phase shifters [J].
Baumann, Bernhard ;
Pircher, Michael ;
Goetzinger, Erich ;
Hitzenberger, Christoph K. .
OPTICS EXPRESS, 2007, 15 (20) :13375-13387
[5]   Real-time spectral domain Doppler optical coherence tomography and investigation of human retinal vessel autoregulation [J].
Bower, Bradley A. ;
Zhao, Mingtao ;
Zawadzki, Robert J. ;
Izatt, Joseph A. .
JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (04)
[6]   Spectral-domain phase microscopy [J].
Choma, MA ;
Ellerbee, AK ;
Yang, CH ;
Creazzo, TL ;
Izatt, JA .
OPTICS LETTERS, 2005, 30 (10) :1162-1164
[7]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[8]  
DAVIS AM, 2005, J BIOMEDICAL OPTICS, V10
[9]   High speed full range complex spectral domain optical coherence tomography [J].
Götzinger, E ;
Pircher, M ;
Leitgeb, RA ;
Hitzenberger, CK .
OPTICS EXPRESS, 2005, 13 (02) :583-594
[10]  
HAMBURGER V, 1951, J MORPHOL, V88, P54