We report a new yet simple method to achieve full-range complex Fourier-domain optical coherence tomography (OCT) for in vivo imaging. The method utilizes a scanner that is dedicated for lateral scanning in the system to introduce a constant carrier frequency into the OCT spectral interferograms during the scanning. This is achieved by simply offsetting the sampling beam spot away from the pivot point of the scanning mirror. We demonstrate the method experimentally for in vivo full-range imaging of the anterior segment of a human eye. The method is free from complex conjugate mirror image and self-cross-correlation image artifacts. (C) 2007 Optical Society of America.
引用
收藏
页码:3423 / 3425
页数:3
相关论文
共 12 条
[1]   Full range complex spectral domain optical coherence tomography without additional phase shifters [J].
Baumann, Bernhard ;
Pircher, Michael ;
Goetzinger, Erich ;
Hitzenberger, Christoph K. .
OPTICS EXPRESS, 2007, 15 (20) :13375-13387
[2]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[3]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[4]   En-face coherence imaging using galvanometer scanner modulation [J].
Podoleanu, AG ;
Dobre, GM ;
Jackson, DA .
OPTICS LETTERS, 1998, 23 (03) :147-149
[5]   Instantaneous complex conjugate resolved spectral domain and swept-source OCT using 3x3 fiber couplers [J].
Sarunic, MV ;
Choma, MA ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2005, 13 (03) :957-967
[6]   Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation [J].
Vakoc, BJ ;
Yun, SH ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2006, 31 (03) :362-364
[7]   In vivo full range complex Fourier domain optical coherence tomography [J].
Wang, Ruikang K. .
APPLIED PHYSICS LETTERS, 2007, 90 (05)
[8]   Real-time flow imaging by removing texture pattern artifacts in spectral-domain optical Doppler tomography [J].
Wang, Ruikang K. ;
Ma, Zhenhe .
OPTICS LETTERS, 2006, 31 (20) :3001-3003
[9]   A practical approach to eliminate autocorrelation artefacts for volume-rate spectral domain optical coherence tomography [J].
Wang, Ruikang K. ;
Ma, Zhenhe .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (12) :3231-3239
[10]   Full range complex spectral optical coherence tomography technique in eye imaging [J].
Wojtkowski, M ;
Kowalczyk, A ;
Leitgeb, R ;
Fercher, AF .
OPTICS LETTERS, 2002, 27 (16) :1415-1417