Instantaneous complex conjugate resolved spectral domain and swept-source OCT using 3x3 fiber couplers

被引:124
作者
Sarunic, MV [1 ]
Choma, MA [1 ]
Yang, CH [1 ]
Izatt, JA [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
来源
OPTICS EXPRESS | 2005年 / 13卷 / 03期
关键词
D O I
10.1364/OPEX.13.000957
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report that the complex conjugate artifact in Fourier domain optical coherence tomography approaches ( including spectral domain and swept source OCT) may be resolved by the use of novel interferometer designs based on 3x3 and higher order fiber couplers. Interferometers built from NxN (N>2) truly fused fiber couplers provide simultaneous access to non-complementary phase components of the complex interferometric signal. These phase components may be converted to quadrature components by trigonometric manipulation, then inverse Fourier transformed to obtain A-scans and images with resolved complex conjugate artifact. We demonstrate instantaneous complex conjugate resolved Fourier domain OCT using 3x3 couplers in both spectral domain and swept source implementations. Complex conjugate artifact suppression by factors of similar to20dB and similar to25dB are demonstrated for spectral domain and swept source implementations, respectively. (C) 2005 Optical Society of America.
引用
收藏
页码:957 / 967
页数:11
相关论文
共 16 条
[1]   Optical coherence tomography using a frequency-tunable optical source [J].
Chinn, SR ;
Swanson, EA ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (05) :340-342
[2]   Instantaneous quadrature low-coherence interferometry with 3 x 3 fiber-optic couplers [J].
Choma, MA ;
Yang, CH ;
Izatt, JA .
OPTICS LETTERS, 2003, 28 (22) :2162-2164
[3]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[4]  
CHOMA MA, 2004, COHERENCE DOMAIN OPT, V8
[5]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[6]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[9]   Phase-shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography [J].
Leitgeb, RA ;
Hitzenberger, CK ;
Fercher, AF ;
Bajraszewski, T .
OPTICS LETTERS, 2003, 28 (22) :2201-2203
[10]   In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve [J].
Nassif, NA ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Yun, SH ;
Bouma, BE ;
Tearney, GJ ;
Chen, TC ;
de Boer, JF .
OPTICS EXPRESS, 2004, 12 (03) :367-376