Time-resolved 3D contrast-enhanced MRA of an extended FOV using continuous table motion

被引:29
作者
Madhuranthakam, AJ [1 ]
Kruger, DG [1 ]
Riederer, SJ [1 ]
Glockner, JF [1 ]
Hu, HCH [1 ]
机构
[1] Mayo Clin, MR Res Lab, Dept Radiol, Coll Med, Rochester, MN 55905 USA
关键词
moving-table MRI; peripheral MRA; time-resolved 3D MRA; extended-FOV MRI; contrast kinetics;
D O I
10.1002/mrm.10729
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method is presented for acquiring 3D time-resolved MR images of an extended (> 100 cm) longitudinal field of view (FOV), as used for peripheral MR angiographic runoff studies. Previous techniques for long-FOV peripheral MRA have generally provided a single image (i.e., with no time resolution). The technique presented here generates a time series of 3D images of the FOV that lies within the homogeneous volume of the magnet. This is achieved by differential sampling of 3D k-space during continuous motion of the patient table. Each point in the object is interrogated in five consecutive 3D image sets generated at 2.5-s intervals. The method was tested experimentally in eight human subjects, and the leading edge of the bolus was observed in real time and maintained within the imaging FOV. The data revealed differential bolus velocities along the vasculature of the legs. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:568 / 576
页数:9
相关论文
共 37 条
[1]   Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory [J].
Barger, AV ;
Block, WF ;
Toropov, Y ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :297-305
[2]   Contrast-enhanced magnetic resonance angiography of peripheral vessels - Different contrast agent applications and sequence strategies: A review [J].
Boos, M ;
Lentschig, M ;
Scheffler, K ;
Bongartz, GM ;
Steinbrich, W .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :538-546
[3]  
Busse RF, 1999, MAGNET RESON MED, V42, P69, DOI 10.1002/(SICI)1522-2594(199907)42:1<69::AID-MRM11>3.0.CO
[4]  
2-Y
[5]   Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels [J].
Du, J ;
Carroll, TJ ;
Wagner, HJ ;
Vigen, K ;
Fain, SB ;
Block, WF ;
Korosec, FR ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) :516-522
[6]   Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation [J].
Earls, JP ;
DeSena, S ;
Bluemke, DA .
RADIOLOGY, 1998, 209 (03) :844-849
[7]   Hepatic arterial-phase dynamic gadolinium-enhanced MR imaging: Optimization with a test examination and a power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1997, 202 (01) :268-273
[8]  
FAIN SB, 2002, P 10 ANN M ISMRM HON, P212
[9]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[10]   Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography [J].
Ho, KYJAM ;
Leiner, T ;
de Haan, MW ;
Kessels, AGH ;
Kitslaar, PJEHM ;
van Engelshoven, JMA .
RADIOLOGY, 1998, 206 (03) :683-692