Generic dealkylation: a tool for increasing the hit-rate of metabolite rationalization, and automatic customization of mass defect filters

被引:46
作者
Mortishire-Smith, Russell J. [1 ]
Castro-Perez, Jose M. [2 ]
Yu, Kate [2 ]
Shockcor, John P.
Goshawk, Jeff [3 ]
Hartshorn, Mike J. [4 ]
Hill, Alastair [4 ]
机构
[1] Johnson & Johnson PR&D, B-2340 Beerse, Belgium
[2] Waters Corp, Milford, MA 01757 USA
[3] Waters MS Technol, Manchester, Lancs, England
[4] Dotmatics, Bishops Stortford CM23 4BE, Herts, England
关键词
BIOLOGICAL MATRICES; HIGH-THROUGHPUT; SPECTROMETRY; IDENTIFICATION; RESOLUTION; SPECTRA;
D O I
10.1002/rcm.3951
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of exact mass liquid chromatography/mass spectrometry (LC/MS) for drug metabolism studies has increased significantly in recent years. Firstly, exact mass measurements facilitate identification of standard biotransformations through the use of narrow window extracted ion chromatograms, which are typically highly selective relative to signals from matrix or dosing components. Secondly, novel metabolites can be characterized via elemental formula calculations and high-resolution product ion spectra. Furthermore, biological background ions can be removed by the use of mass defect filters (MDFs) which filter out ions based on the decimal component of their m/z value. Here, we describe an approach which we term 'generic dealkylation' that in association with other data interpretation tools adds significant value to the assignment process. Generic dealkylation uses a simple strategy to identify those bonds which have the potential to be cleaved by metabolism. In combination with standard phase 1 and phase 2 biotransformations, this allows creation of a chemically intelligent MDF which balances the need to remove matrix background with the requirement of avoiding filtering true metabolites. Secondly, generic dealkylation increases the hit-rate at which non-trivial (i.e. not covered by simple phase 1 oxidations or direct phase 2 conjugations) metabolites can be directly rationalized. The value of the generic dealkylation approach is illustrated by its application to determination of in vitro metabolic routes for two commercial drugs, nefazodone and indinavir. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:939 / 948
页数:10
相关论文
共 22 条
[11]   Application of a linear ion trap/orbitrap mass spectrometer in metabolite characterization studies: Examination of the human liver microsomal metabolism of the non-tricyclic anti-depressant nefazodone using data-dependent accurate mass measurements [J].
Peterman, SM ;
Duczak, N ;
Kalgutkar, AS ;
Lame, ME ;
Soglia, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (03) :363-375
[12]   CONVEX HULLS OF FINITE SETS OF POINTS IN 2 AND 3 DIMENSIONS [J].
PREPARATA, FP ;
HONG, SJ .
COMMUNICATIONS OF THE ACM, 1977, 20 (02) :87-93
[13]   An integrated method for metabolite detection and identification using a linear ion trap/Orbitrap mass spectrometer and multiple data processing techniques: application to indinavir metabolite detection [J].
Ruan, Qian ;
Peterman, Scott ;
Szewc, Mark A. ;
Ma, Li ;
Cui, Dan ;
Humphreys, W. Griffith ;
Zhu, Mingshe .
JOURNAL OF MASS SPECTROMETRY, 2008, 43 (02) :251-261
[14]   Relative mass defect filtering of high-resolution mass spectra for exploring minor selenium volatiles in selenium-enriched green onions [J].
Shah, Monika ;
Meija, Juris ;
Caruso, Joseph A. .
ANALYTICAL CHEMISTRY, 2007, 79 (03) :846-853
[15]   High-throughput, accurate mass liquid chromatography/tandem mass spectrometry on a quadrupole time-of-flight system as a 'first-line' approach for metabolite identification studies [J].
Tiller, Philip R. ;
Yu, Sean ;
Castro-Perez, Jose ;
Fillgrove, Kerry L. ;
Baillie, Thomas A. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (07) :1053-1061
[16]   'All-in-One' analysis for metabolite identification using liquid chromatography/hybrid quadrupole time-of-flight mass spectrometry with collision energy switching [J].
Wrona, M ;
Mauriala, T ;
Bateman, KP ;
Mortishire-Smith, RJ ;
O'Connor, D .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (18) :2597-2602
[17]  
Xu GF, 2008, LC GC EUR, P39
[18]   Mass defect profiles of biological matrices and the general applicability of mass defect filtering for metabolite detection [J].
Zhang, Haiying ;
Zhu, Mingshe ;
Ray, Kenneth L. ;
Ma, Li ;
Zhang, Donglu .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (13) :2082-2088
[19]   A software filter to remove interference ions from drug metabolites in accurate mass liquid chromatography/mass spectrometric analyses [J].
Zhang, HY ;
Zhang, DL ;
Ray, K .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (10) :1110-1112
[20]   Detection and structural characterization of glutathione-trapped reactive metabolites using liquid chromatography-high-resolution mass Spectrometry and mass defect filtering [J].
Zhu, Mingshe ;
Ma, Li ;
Zhang, Haiying ;
Humphreys, W. Griffith .
ANALYTICAL CHEMISTRY, 2007, 79 (21) :8333-8341