Indoor biological contaminants and symptoms of sick building syndrome in office buildings in Mauritius

被引:34
作者
Bholah, R [1 ]
Subratty, AH [1 ]
机构
[1] Univ Mauritius, Fac Sci, Dept Hlth & Med Sci, Reduit, Mauritius
关键词
sick building; syndrome; bioaerosol; fungus; bacteria; mites; health; Mauritius;
D O I
10.1080/09603120120110095
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study was carried out to investigate possible relationship between bio-contaminants and symptoms of sick building syndrome among office workers in Mauritius. Viable microbial colonies were collected using a Casella slit sampler in 23 selected indoor office buildings. A questionnaire survey as well as a walk through investigation was undertaken. Physico-chemical measurements were also monitored in the selected offices. Results of this study showed that number of indoor bacterial bioaerosol concentrations ranged between 3 and 1110 CFU/m(3) while fungal counts were 0-196 CFU/m(3). However, most of the buildings showed absence of dust mites. In conclusions fungal contamination was found to be associated with the onset of sick building syndrome symptoms among workers in office buildings in Mauritius.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 14 条
[11]  
SUBRATTY AH, 1995, ANN ALLERG ASTHMA IM, V74, P489
[12]   ASSOCIATIONS BETWEEN TYPE OF VENTILATION AND AIR-FLOW RATES IN OFFICE BUILDINGS AND THE RISK OF SBS-SYMPTOMS AMONG OCCUPANTS [J].
SUNDELL, J ;
LINDVALL, T ;
STENBERG, B .
ENVIRONMENT INTERNATIONAL, 1994, 20 (02) :239-251
[13]   Sick-building symptoms in office workers in northeastern France: a pilot study [J].
Teculescu, DB ;
Sauleau, EA ;
Massin, N ;
Bohadana, AB ;
Buhler, O ;
Benamghar, L ;
Mur, JM .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1998, 71 (05) :353-356
[14]  
*WHO REG OFF EUR, 1983, WHO REG PUBL EUR SER, V78