Reliability and Validity Study of Clinical Ultrasound Imaging on Lateral Curvature of Adolescent Idiopathic Scoliosis

被引:45
作者
Wang, Q. [1 ,2 ,3 ]
Li, M. [1 ]
Lou, Edmond H. M. [4 ]
Wong, M. S. [1 ]
机构
[1] Hong Kong Polytech Univ, Interdisciplinary Div Biomed Engn, Hong Kong, Hong Kong, Peoples R China
[2] Sichuan Univ, West China Hosp, Ctr Rehabil Med, Chengdu 610064, Peoples R China
[3] Hong Kong Polytech Univ, Sichuan Univ, Inst Disaster Management & Reconstruct, Chengdu, Peoples R China
[4] Univ Alberta, Dept Surg, Glenrose Rehabil Res Ctr, Edmonton, AB, Canada
关键词
INTRAOBSERVER RELIABILITY; SPINAL CURVATURE; COBB-ANGLE; INTEROBSERVER; RADIOGRAPHS; AIS;
D O I
10.1371/journal.pone.0135264
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
Background Non-ionizing radiation imaging assessment has been advocated for the patients with adolescent idiopathic scoliosis (AIS). As one of the radiation-free methods, ultrasound imaging has gained growing attention in scoliosis assessment over the past decade. The center of laminae (COL) method has been proposed to measure the spinal curvature in the coronal plane of ultrasound image. However, the reliability and validity of this ultrasound method have not been validated in the clinical setting. Objectives To evaluate the reliability and validity of clinical ultrasound imaging on lateral curvature measurements of AIS with their corresponding magnetic resonance imaging (MRI) measurements. Methods Thirty curves (ranged 10.2 degrees-68.2 degrees) from sixteen patients with AIS were eligible for this study. The ultrasound scan was performed using a 3-D ultrasound unit within the same morning of MRI examination. Two researchers were involved in data collection of these two examinations. The COL method was used to measure the coronal curvature in ultrasound image, compared with the Cobb method in MRI. The intra-and inter-rater reliability of the COL method was evaluated by intra-class correlation coefficient (ICC). The validity of this method was analyzed by paired Student's t-test, Bland-Altman statistics and Pearson correlation coefficient. The level of significance was set as 0.05. Results The COL method showed high intra-and inter-rater reliabilities (both with ICC (2, K) > 0.9, p<0.05) to measure the coronal curvature. Compared with Cobb method, COL method showed no significant difference (p<0.05) when measuring coronal curvature. Furthermore, Bland-Altman method demonstrated an agreement between these two methods, and Pearson's correlation coefficient (r) was high (r>0.9, p<0.05). Conclusion The ultrasound imaging could provide a reliable and valid measurement of spinal curvature in the coronal plane using the COL method. Further research is needed to validate the proposed ultrasound measurement in larger clinical trial and to optimize the ultrasound scanning and measuring procedure.
引用
收藏
页数:16
相关论文
共 31 条
[1]
COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[2]
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[3]
Intra- and interobserver reliability of the cobb angle-vertebral rotation angle-spinous process angle for adolescent idiopathic scoliosis [J].
Chan A.C.Y. ;
Morrison D.G. ;
Nguyen D.V. ;
Hill D.L. ;
Parent E. ;
Lou E.H.M. .
Spine Deformity, 2014, 2 (3) :168-175
[4]
Chen W, 2011, ENG MED BIOL SOC EMB
[5]
Chen W., 2012, OPEN J ACOUSTICS, V2, P95, DOI [10.4236/oja.2012.23011, DOI 10.4236/OJA.2012.23011]
[6]
Reliability of assessing the coronal curvature of children with scoliosis by using ultrasound images [J].
Chen, Wei ;
Lou, Edmond H. M. ;
Zhang, Phoebe Q. ;
Le, Lawrence H. ;
Hill, Doug .
JOURNAL OF CHILDRENS ORTHOPAEDICS, 2013, 7 (06) :521-529
[7]
Cheung CWJ, 2013, IEEE ENG MED BIO, P6474, DOI 10.1109/EMBC.2013.6611037
[8]
Currier D.P., 1984, ELEMENTS RES PHYS TH, V2nd
[9]
Inter- and intraobserver reliability assessment of the Cobb angle: manual versus digital measurement tools [J].
Gstoettner, Michaela ;
Sekyra, Katrin ;
Walochnik, Nadja ;
Winter, Peter ;
Wachter, Roland ;
Bach, Christian M. .
EUROPEAN SPINE JOURNAL, 2007, 16 (10) :1587-1592
[10]
Centroid Method: Reliable Method to Determine the Coronal Curvature of Scoliosis A Case Control Study Comparing with the Cobb Method [J].
Hong, Jae-Young ;
Suh, Seung-Woo ;
Modi, Hitesh N. ;
Hur, Chang-Yong ;
Song, Hae-Ryong ;
Ryu, Joo-Hyung .
SPINE, 2011, 36 (13) :E855-E861