Ion Mobility-Mass Spectrometer Interface for Collisional Activation of Mobility Separated Ions

被引:15
作者
Fernandez-Lima, Francisco A. [1 ]
Becker, Christopher [1 ]
Gillig, Kent J. [1 ]
Russell, William K. [1 ]
Tichy, Shane E. [1 ]
Russell, David H. [1 ]
机构
[1] Texas A&M Univ, Dept Chem, College Stn, TX 77843 USA
基金
美国国家科学基金会;
关键词
LASER-DESORPTION IONIZATION; RESOLVED MAGNETIC DISPERSION; POST-SOURCE DECAY; INDUCED DISSOCIATION; LIQUID-CHROMATOGRAPHY; BIOMOLECULAR IONS; DRIFT-TUBE; GAS-PHASE; TRAP; REFLECTRON;
D O I
10.1021/ac801919n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ion mobility-mass spectrometer (IM-MS) interface is described that can be employed to perform collisional activation and/or collision-induced dissociation (CID) with good transmission of mobility separated ions to the MS analyzer. The IM-MS interface consists of a stacked-ring ion guide design, where the field strength and pressure ratio can be operated such that structural rearrangement reactions and/or CID are achieved as a function of the effective ion temperature. The ion dynamics and collisional activation processes in the IM-MS interface are described as a function of the ion-neutral collisions, ion kinetic energies, and effective ion temperature. The applicability of the IM-CID-MS methodology to studies of peptide ion fragmentation is illustrated using a series of model peptides.
引用
收藏
页码:618 / 624
页数:7
相关论文
共 67 条
[21]  
Fournier I, 2000, J MASS SPECTROM, V35, P1425
[22]  
FUHRER K, 2005, Patent No. 20050189486
[23]   SUSTAINED OFF-RESONANCE IRRADIATION FOR COLLISION-ACTIVATED DISSOCIATION INVOLVING FOURIER-TRANSFORM MASS-SPECTROMETRY - COLLISION-ACTIVATED DISSOCIATION TECHNIQUE THAT EMULATES INFRARED MULTIPHOTON DISSOCIATION [J].
GAUTHIER, JW ;
TRAUTMAN, TR ;
JACOBSON, DB .
ANALYTICA CHIMICA ACTA, 1991, 246 (01) :211-225
[24]   An electrostatic focusing ion guide for ion mobility-mass spectrometry [J].
Gillig, KJ ;
Ruotolo, BT ;
Stone, EG ;
Russell, DH .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 239 (01) :43-49
[25]   Coupling high-pressure MALDI with ion mobility/orthogonal time-of flight mass spectrometry [J].
Gillig, KJ ;
Ruotolo, B ;
Stone, EG ;
Russell, DH ;
Fuhrer, K ;
Gonin, M ;
Schultz, AJ .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :3965-3971
[26]  
Gillig KJ, 2001, Patent Cooperation Treaty Int. Appl, Patent No. [WO0165589, 0165589]
[27]   Collision-induced dissociation in quadrupole ion traps: Application of a thermal model to diatomic ions [J].
Goeringer, DE ;
Duckworth, DC ;
McLuckey, SA .
JOURNAL OF PHYSICAL CHEMISTRY A, 2001, 105 (10) :1882-1889
[28]   Estimation of effective ion temperatures in a quadrupole ion trap [J].
Gronert, S .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (08) :845-848
[29]   RELATIVE DISSOCIATION-ENERGY MEASUREMENTS USING ION-TRAP COLLISIONAL ACTIVATION [J].
HART, KJ ;
MCLUCKEY, SA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (04) :250-259
[30]   Matrix-assisted laser desorption/ionisation, an experience [J].
Hillenkamp, F ;
Karas, M .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 200 (1-3) :71-77