The aim of the current study was to (a) provide normalized dose data for the estimation of the radiation dose from upper gastrointestinal tract contrast (UGIC) studies carried out to infants and (b) estimate the average patient dose and risks associated with radiation from UGIC examinations performed in our institution. Organ and effective doses, normalized to entrance skin dose (ESD) and dose area product (DAP) were estimated for UGIC procedures utilizing the Monte Carlo N-particle (MCNP) transport code and two mathematical phantoms, one corresponding to the size of a newborn and one to the size of a 1-year-old child. The validity of the MCNP results was verified by comparison with dose data obtained in physical anthropomorphic phantoms simulating a newborn and a 1-year-old infant using thermoluminescence dosimetry (TLD). Data were also collected from 25 consecutive UGIC examinations performed to infants. Study participants were (a) 12 infants aged from 0.5 to 5.9 months (group 1) and (b) 13 infants aged from 6 to 15 months (group 2). For each examination, ESD and dose to comforters were measured using TLD. Patient effective doses were estimated using normalized dose data obtained in the simulation study. The risk for fatal cancer induction was estimated using appropriate coefficients. The results consist of tabulated dose data normalized to ESD or DAP for the estimation of patient dose. Conversion coefficients were estimated for various tube potentials and beam filtration values. The mean total fluoroscopy time was 1.26 and 1.62 min for groups 1 and 2, respectively. The average effective dose was 1.6 mSv for group 1 and 1.9 mSv for group 2. The risk of cancer attributable to the radiation exposure associated with a typical UGIC study was found to be up to 3 per 10 000 infants undergoing an UGIC examination. The mean radiation dose absorbed by the hands of comforters was 47 AGy. In conclusion, estimation of radiation doses associated with UGIC studies performed to infants can be made using the normalized dose data provided in the current study. Radiation dose values associated with UGIC examinations carried out to infants are not low and should be minimized as much as possible. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1033 / 1040
页数:8
相关论文
共 13 条
[1]   Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[2]  
CARTY H, 2001, ENCY MED IMAGING, P237
[3]   Normalized conceptus doses for abdominal radiographic examinations calculated using a Monte Carlo technique [J].
Damilakis, J ;
Tzedakis, A ;
Sideri, L ;
Perisinakis, K ;
Stamatelatos, IE ;
Gourtsoyiannis, N .
MEDICAL PHYSICS, 2002, 29 (11) :2641-2648
[4]   Lessons we have learned from our children: cancer risks from diagnostic radiology [J].
Hall, EJ .
PEDIATRIC RADIOLOGY, 2002, 32 (10) :700-706
[5]  
Hart D., 1996, COEFFICIENTS ESTIMAT
[6]   Effective dose and energy imparted in diagnostic radiology [J].
Huda, W ;
Gkanatsios, NA .
MEDICAL PHYSICS, 1997, 24 (08) :1311-1316
[7]  
International Commission on Radiological Protection, 1991, 1990 REC INT COMM RA
[8]   Influence of patient age on normalized effective doses calculated for CT examinations [J].
Khursheed, A ;
Hillier, MC ;
Shrimpton, PC ;
Wall, BF .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (898) :819-830
[9]   Fetal dose assessment from invasive special procedures by Monte Carlo methods [J].
Metzger, RL ;
Van Riper, KA .
MEDICAL PHYSICS, 1999, 26 (08) :1714-1720
[10]  
National Research Council, 1990, HLTH EFF EXP LOW LEV