In vivo monitoring of amino acids by direct sampling of brain extracellular fluid at ultralow flow rates and capillary electrophoresis

被引:90
作者
Kennedy, RT
Thompson, JE
Vickroy, TW
机构
[1] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Physiol Sci, Gainesville, FL 32611 USA
关键词
microdialysis; excitatory amino acids; glutamate; GABA; direct sampling; in vivo monitoring; laser-induced fluorescence;
D O I
10.1016/S0165-0270(01)00506-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Extracellular levels of glutamate (GLU), aspartate (ASP), glycine (GLY), phosphoethanolarnine (PEA), and gamma-aminobutyric acid (GABA) were measured in the striatum of anesthetized rats using a novel sampling approach in which extracellular fluid (ECF) was removed at 1-50 nl/min using a fused silica capillary tube with 18-40 mum inner diameter and a outer diameter of 90 gm. The samples of ECF were analyzed by capillary electrophoresis with laser-induced fluorescence detection. Basal levels for GABA, GLY, and GLU measured using direct sampling at 1 nl/min were 270 +/- 40, 4950 +/- 1100, and 1760 +/- 150 nM, respectively in good agreement with the values obtained using microdialysis sampling calibrated by the low-flow rate method. ASP levels were approximately four-fold higher in directly sampled fluid than in dialysate. At higher direct sampling flow rates (10-50 nl/min), detected levels of the amino acids were lower by 70-90% indicating depiction of analyte under these conditions. PEA, an indicator of membrane disruption, was 5.5-fold higher in dialysate than in directly sampled ECF indicating greater tissue damage associated with microdialysis. In addition to the basal measurements, the direct sampling technique was applied to monitoring concentration changes of GLU and ASP in the striatum with better than 90 s temporal resolution after perfusion of either 120 mM K+ or 400 muM L-trans-pyrrolidine-2,4-dicarboxylic acid (PDC) through a microdialysis probe immediately adjacent to the direct sampling capillary. Levels of GLU and ASP increased 615 +/- 95 and 542 +/- 96%, respectively (n = 4) upon addition of 120 mM K I to the perfusate and 622 +/- 234 and 672 +/- 218% (n = 5) for PDC. It is concluded that direct sampling at low-flow rates allows determination of extracellular levels of the amino acids with spatial resolution that is at least 500-fold better than microdialysis. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:39 / 49
页数:11
相关论文
共 33 条
[1]   BRAIN MICRODIALYSIS [J].
BENVENISTE, H .
JOURNAL OF NEUROCHEMISTRY, 1989, 52 (06) :1667-1679
[2]   Trace-level amino acid analysis by capillary liquid chromatography and application to in vivo microdialysis sampling with 10-s temporal resolution [J].
Boyd, BW ;
Witowski, SR ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :865-871
[3]   Probe calibration in transient microdialysis in vivo [J].
Bungay, PM ;
Dedrick, RL ;
Fox, E ;
Balis, FM .
PHARMACEUTICAL RESEARCH, 2001, 18 (03) :361-366
[4]   Self referencing ceramic based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes [J].
Burmeister, JJ ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :1037-1042
[5]   MICRODIALYSIS SAMPLING COUPLED ONLINE TO FAST MICROBORE LIQUID-CHROMATOGRAPHY [J].
CHEN, AQ ;
LUNTE, CE .
JOURNAL OF CHROMATOGRAPHY A, 1995, 691 (1-2) :29-35
[6]   RAPID SAMPLING AND DETERMINATION OF EXTRACELLULAR DOPAMINE INVIVO [J].
CHURCH, WH ;
JUSTICE, JB .
ANALYTICAL CHEMISTRY, 1987, 59 (05) :712-716
[7]   Quantitative microdialysis of serotonin and norepinephrine: Pharmacological influences on in vivo extraction fraction [J].
Cosford, RJO ;
Vinson, AP ;
Kukoyi, S ;
Justice, JB .
JOURNAL OF NEUROSCIENCE METHODS, 1996, 68 (01) :39-47
[8]  
ERERCINSKA M, 1990, PROG NEUROBIOL, V35, P245
[9]  
GADDUM JH, 1961, J PHYSIOL-LONDON, V155, pP1
[10]   Development and comparison of biosensors for in-vivo applications [J].
Georganopoulou, DG ;
Carley, R ;
Jones, DA ;
Boutelle, MG .
FARADAY DISCUSSIONS, 2000, 116 :291-303