The UF series of tomographic computational phantoms of pediatric patients

被引:80
作者
Lee, C
Williams, JL
Lee, C
Bolch, WE [1 ]
机构
[1] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Radiol, Gainesville, FL 32610 USA
[3] Univ Florida, Dept Biomed Engn, Gainesville, FL 32610 USA
[4] Univ Florida, Dept Nucl & Radiol, Gainesville, FL 32610 USA
关键词
pediatrics; tomographic phantom; voxel phantom; radiation dosimetry;
D O I
10.1118/1.2107067
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two classes of anthropomorphic computational phantoms exist for use in Monte Carlo radiation transport simulations: tomographic voxel phantoms based upon three-dimensional (313) medical images, and stylized mathematical phantoms based upon 3D surface equations for internal organ definition. Tomographic phantoms have shown distinct advantages over the stylized phantoms regarding their similarity to real human anatomy. However, while a number of adult tomographic phantoms have been developed since the early 1990s, very few pediatric tomographic phantoms are presently available to support dosimetry in pediatric diagnostic and therapy examinations. As part of a larger effort to construct a series of tomographic phantoms of pediatric patients, five phantoms of different ages (9-month male, 4-year female, 8-year female, 11-year male, and 14-year male) have been constructed from computed tomography (CT) image data of live patients using an IDL-based image segmentation tool. Lungs, bones, and adipose tissue were automatically segmented through use of window leveling of the original CT numbers. Additional organs were segmented either semiautomatically or manually with the aid of both anatomical knowledge and available image-processing techniques. Layers of skin were created by adding voxels along the exterior contour of the bodies. The phantoms were created from fused images taken from head and chest-abdomen-pelvis CT exams of the same individuals (9-month and 4-year phantoms) or of two different individuals of the same sex and similar age (8-year, 11-year, and 14-year phantoms). For each model, the resolution and slice positions of the image sets were adjusted based upon their anatomical coverage and then fused to a single head-torso image set. The resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year, and 14-year are 0.43 X 0.43 X 3.0 mm, 0.45 X 0.45 X 5.0 mm, 0.58 X 0.58 X 6.0 mm, 0.47 X 0.47 X 6.00 mm, and 0.625 X 0.625 X 6.0 mm, respectively. While organ masses can be matched to reference values in both stylized and tomographic phantoms, side-by-side comparisons of organ doses in both phantom classes indicate that organ shape and positioning are equally important parameters to consider in accurate determinations of organ absorbed dose from external photon irradiation. Preliminary studies of external photon irradiation of the 11-year phantom indicate significant departures of organ dose coefficients from that predicted by the existing stylized phantom series. Notable differences between pediatric stylized and tomographic phantoms include anterior-posterior (AP) and right lateral (RLAT) irradiation of the stomach wall, left lateral (LLAT) and right lateral (RLAT) irradiation of the thyroid, and AP and posterior-anterior (PA) irradiation of the urinary bladder. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:3537 / 3548
页数:12
相关论文
共 36 条
[1]  
[Anonymous], HLTH EFF EXP LOW LEV
[2]  
[Anonymous], 2013, About the National Health and Nutrition Examination Survey
[3]   A video analysis technique for organ dose assessment in pediatric fluoroscopy: Applications to voiding cystourethrograms (VCUG) [J].
Bolch, WE ;
Pomije, BD ;
Sessions, JB ;
Arreola, MM ;
Williams, JL ;
Pazik, FD .
MEDICAL PHYSICS, 2003, 30 (04) :667-680
[4]  
BOTTCHET L, 2003, J NUCL MED, V44, P1113
[5]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[6]   An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations [J].
Caon, M ;
Bibbo, G ;
Pattison, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09) :2213-2225
[7]   Conversion coefficients based on the VIP-MAN anatomical model and EGS4-VLSI code for external monoenergetic photons from 10 keV to 10 MeV [J].
Chao, TC ;
Bozkurt, A ;
Xu, XG .
HEALTH PHYSICS, 2001, 81 (02) :163-183
[8]  
CRISTY M, 1987, ORNLTM8381, V1
[9]   FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz [J].
Dimbylow, PJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (03) :479-490
[10]  
HAN E, IN PRESS HLTH PHYS