Passive leg raising predicts fluid responsiveness in the critically ill

被引:545
作者
Monnet, X [1 ]
Rienzo, M
Osman, D
Anguel, N
Richard, C
Pinsky, MR
Teboul, JL
机构
[1] Univ Paris 11, Assistance Publ Hop Paris, Ctr Hosp Univ Bicetre, Serv Reanimat Med, Le Kremlin Bicetre, France
[2] Univ Pittsburgh, Dept Crit Care Med, Pittsburgh, PA USA
关键词
fluid responsiveness; leg raising; pulse pressure variation; aortic blood flow;
D O I
10.1097/01.CCM.0000215453.11735.06
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Passive leg raising (PLR) represents a "self-volume challenge" that could predict fluid response and might be useful when the respiratory variation of stroke volume cannot be used for that purpose. We hypothesized that the hemodynamic response to PLR predicts fluid responsiveness in mechanically ventilated patients. Design. Prospective study. Setting. Medical intensive care unit of a university hospital. Patients. We investigated 71 mechanically ventilated patients considered for volume expansion. Thirty-one patients had spontaneous breathing activity and/or arrhythmias. Interventions: We assessed hemodynamic status at baseline, after PLR, and after volume expansion (500 mL NaCl 0.9% infusion over 10 mins). Measurements and Main Results: We recorded aortic blood flow using esophageal Doppler and arterial pulse pressure. We calculated the respiratory variation of pulse pressure in patients without arrhythmias. In 37 patients (responders), aortic blood flow increased by >= 15% after fluid infusion. A PLR increase of aortic blood flow >= 10% predicted fluid responsiveness with a sensitivity of 97% and a specificity of 94%. A PLR increase of pulse pressure >= 12% predicted volume responsiveness with significantly lower sensitivity (60%) and specificity (85%). In 30 patients without arrhythmias or spontaneous breathing, a respiratory variation in pulse pressure >= 12% was of similar predictive value as was PLR increases in aortic blood flow (sensitivity of 88% and specificity of 93%). In patients with spontaneous breathing activity, the specificity of respiratory variations in pulse pressure was poor (46%). Conclusions: The changes in aortic blood flow induced by PLR predict preload responsiveness in ventilated patients, whereas with arrhythmias and spontaneous breathing activity, respiratory variations of arterial pulse pressure poorly predict preload responsiveness.
引用
收藏
页码:1402 / 1407
页数:6
相关论文
共 26 条
[1]  
Berkenstadt H, 2001, ANESTH ANALG, V92, P984
[2]   Continuous noninvasive measurement of aortic blood flow in critically ill patients with a new esophageal echo-Doppler system [J].
Bernardin, G ;
Tiger, F ;
Fouché, R ;
Mattéi, M .
JOURNAL OF CRITICAL CARE, 1998, 13 (04) :177-183
[3]   Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients [J].
Boulain, T ;
Achard, JM ;
Teboul, JL ;
Richard, C ;
Perrotin, D ;
Ginies, G .
CHEST, 2002, 121 (04) :1245-1252
[4]   Non-invasive cardiac output monitoring by aortic blood flow measurement with the Dynemo 3000 [J].
Boulnois, JLG ;
Pechoux, T .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2000, 16 (02) :127-140
[5]   Noninvasive cardiac output monitoring by aortic blood flow determination:: Evaluation of the Sometec Dynemo-3000 system [J].
Cariou, A ;
Monchi, M ;
Joly, LM ;
Bellenfant, F ;
Claessens, YE ;
Thébert, D ;
Brunet, F ;
Dhainaut, JF .
CRITICAL CARE MEDICINE, 1998, 26 (12) :2066-2072
[6]   Total arterial compliance estimated by stroke volume to aortic pulse pressure ratio in humans [J].
Chemla, D ;
Hébert, JL ;
Coirault, C ;
Zamani, K ;
Suard, I ;
Colin, P ;
Lecarpentier, Y .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (02) :H500-H505
[7]   The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults [J].
Dark, PM ;
Singer, M .
INTENSIVE CARE MEDICINE, 2004, 30 (11) :2060-2066
[8]   Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock [J].
Feissel, M ;
Michard, F ;
Mangin, I ;
Ruyer, O ;
Faller, JP ;
Teboul, JL .
CHEST, 2001, 119 (03) :867-873
[9]   PASSIVE LEG RAISING DOES NOT PRODUCE A SIGNIFICANT OR SUSTAINED AUTO-TRANSFUSION EFFECT [J].
GAFFNEY, FA ;
BASTIAN, BC ;
THAL, ER ;
ATKINS, JM ;
BLOMQVIST, CG .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1982, 22 (03) :190-193
[10]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843