Optimal control of force microscope cantilevers .2. Magnetic coupling implementation

被引:40
作者
Bruland, KJ [1 ]
Garbini, JL [1 ]
Dougherty, WM [1 ]
Sidles, JA [1 ]
机构
[1] UNIV WASHINGTON,DEPT ORTHOPAED,SEATTLE,WA 98195
关键词
D O I
10.1063/1.363086
中图分类号
O59 [应用物理学];
学科分类号
摘要
We describe the implementation of optimal controllers for damping the motion of cantilevers used in magnetic resonance force microscopy. We demonstrate that optimal control is achievable and that torsional magnetic coupling provides an effective actuation method. Cantilever Brownian vibrational amplitude was reduced from 2 to 0.16 Angstrom and resonant quality was reduced from 2000 to 5. Applied control fields were sufficiently small that they would not affect magnetic resonance phenomena. (C) 1996 American Institute of Physics.
引用
收藏
页码:1959 / 1964
页数:6
相关论文
共 14 条
  • [1] ANHARMONIC MODULATION FOR NOISE-REDUCTION IN MAGNETIC-RESONANCE FORCE MICROSCOPY
    BRULAND, KJ
    KRZYSTEK, J
    GARBINI, JL
    SIDLES, JA
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (04) : 2853 - 2856
  • [2] Optimal control of force microscope cantilevers .1. Controller design
    Garbini, JL
    Bruland, KJ
    Dougherty, WM
    Sidles, JA
    [J]. JOURNAL OF APPLIED PHYSICS, 1996, 80 (04) : 1951 - 1958
  • [3] HOEN S, 1994, 1994 SOL STAT SENS A, P209
  • [4] CALIBRATION OF ATOMIC-FORCE MICROSCOPE TIPS
    HUTTER, JL
    BECHHOEFER, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (07) : 1868 - 1873
  • [5] REGULATION OF A MICROCANTILEVER RESPONSE BY FORCE FEEDBACK
    MERTZ, J
    MARTI, O
    MLYNEK, J
    [J]. APPLIED PHYSICS LETTERS, 1993, 62 (19) : 2344 - 2346
  • [6] MECHANICAL DETECTION OF MAGNETIC-RESONANCE
    RUGAR, D
    YANNONI, CS
    SIDLES, JA
    [J]. NATURE, 1992, 360 (6404) : 563 - 566
  • [7] FORCE DETECTION OF NUCLEAR-MAGNETIC-RESONANCE
    RUGAR, D
    ZUGER, O
    HOEN, S
    YANNONI, CS
    VIETH, HM
    KENDRICK, RD
    [J]. SCIENCE, 1994, 264 (5165) : 1560 - 1563
  • [8] IMPROVED FIBER-OPTIC INTERFEROMETER FOR ATOMIC FORCE MICROSCOPY
    RUGAR, D
    MAMIN, HJ
    GUETHNER, P
    [J]. APPLIED PHYSICS LETTERS, 1989, 55 (25) : 2588 - 2590
  • [9] FORCE MICROSCOPE USING A FIBER-OPTIC DISPLACEMENT SENSOR
    RUGAR, D
    MAMIN, HJ
    ERLANDSSON, R
    STERN, JE
    TERRIS, BD
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (11) : 2337 - 2340
  • [10] SIGNAL-TO-NOISE RATIOS IN INDUCTIVE AND MECHANICAL DETECTION OF MAGNETIC-RESONANCE
    SIDLES, JA
    RUGAR, D
    [J]. PHYSICAL REVIEW LETTERS, 1993, 70 (22) : 3506 - 3509