On the biomechanical role of glycosaminoglycans in the aortic heart valve leaflet

被引:60
作者
Eckert, Chad E. [1 ]
Fan, Rong [2 ]
Mikulis, Brandon [1 ]
Barron, Mathew [1 ]
Carruthers, Christopher A. [1 ]
Friebe, Vincent M. [3 ]
Vyavahare, Naren R. [3 ]
Sacks, Michael S. [2 ]
机构
[1] Univ Pittsburgh, Swanson Sch Engn, Dept Bioengn, Pittsburgh, PA USA
[2] Univ Texas Austin, Inst Computat Engn & Sci, Dept Biomed Engn, Austin, TX 78712 USA
[3] Clemson Univ, Dept Bioengn, Cardiovasc Implant Res Lab, Clemson, SC USA
关键词
Glycosaminoglycan; Heart valve; Mechanical properties; Mechanical test; MEDIAL COLLATERAL LIGAMENT; BIAXIAL MECHANICAL-PROPERTIES; INTERNAL SHEAR PROPERTIES; STRESS-RELAXATION; BIOPROSTHETIC VALVES; ANTERIOR LEAFLET; HETEROGRAFT BIOMATERIALS; GLUTARALDEHYDE FIXATION; EXTRACELLULAR-MATRIX; FIBER RECRUITMENT;
D O I
10.1016/j.actbio.2012.09.031
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
While the role of collagen and elastin fibrous components in heart valve valvular biomechanics has been extensively investigated, the biomechanical role of the glycosaminoglycan (GAG) gelatinous-like material phase remains unclear. In the present study, we investigated the biomechanical role of GAGs in porcine aortic valve (AV) leaflets under tension utilizing enzymatic removal. Tissue specimens were removed from the belly region of porcine AVs and subsequently treated with either an enzyme solution for GAG removal or a control (buffer with no enzyme) solution. A dual stress level test methodology was used to determine the effects at low and high (physiological) stress levels. In addition, planar biaxial tests were conducted both on-axis (i.e. aligned to the circumferential and radial axes) and at 45 degrees off-axis to induce maximum shear, to explore the effects of augmented fiber rotations on the fiber-fiber interactions. Changes in hysteresis were used as the primary metric of GAG functional assessment. A simulation of the low-force experimental setup was also conducted to clarify the internal stress system and provide viscoelastic model parameters for this loading range. Results indicated that under planar tension the removal of GAGs had no measureable affect extensional mechanical properties (either on- or 45 degrees off-axis), including peak stretch, hysteresis and creep. Interestingly, in the low-force range, hysteresis was markedly reduced, from 35.96 +/- 2.65% in control group to 25.00 +/- 1.64% (p < 0.001) as a result of GAG removal. Collectively, these results suggest that GAGs do not play a direct role in modulating the time-dependent tensile properties of valvular tissues. Rather, they appear to be strongly connected with fiber-fiber and fiber-matrix interactions at low force levels. Thus, we speculate that GAGs may be important in providing a damping mechanism to reduce leaflet flutter when the leaflet is not under high tensile stress. (C) 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:4653 / 4660
页数:8
相关论文
共 58 条
[21]   The effects of collagen fiber orientation on the flexural properties of pericardial heterograft biomaterials [J].
Mirnajafi, A ;
Raymer, J ;
Scott, MJ ;
Sacks, MS .
BIOMATERIALS, 2005, 26 (07) :795-804
[22]   The flexural rigidity of the aortic valve leaflet in the commissural region [J].
Mirnajafi, Ali ;
Raymer, Jeremy M. ;
McClure, Leigh R. ;
Sacks, Michael S. .
JOURNAL OF BIOMECHANICS, 2006, 39 (16) :2966-2973
[23]   Nonlinear ligament viscoelasticity [J].
Provenzano, P ;
Lakes, R ;
Keenan, T ;
Vanderby, R .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (10) :908-914
[24]   BIOMECHANICAL AND STRUCTURAL-PROPERTIES OF THE EXPLANTED BIOPROSTHETIC VALVE LEAFLETS [J].
PURINYA, B ;
KASYANOV, V ;
VOLKOLAKOV, J ;
LATSIS, R ;
TETERE, G .
JOURNAL OF BIOMECHANICS, 1994, 27 (01) :1-11
[25]   Neomycin binding preserves extracellular matrix in bioprosthetic heart valves during in vitro cyclic fatigue and storage [J].
Raghavan, Devanathan ;
Starcher, Barry C. ;
Vyavahare, Naren R. .
ACTA BIOMATERIALIA, 2009, 5 (04) :983-992
[26]  
Reul H., 1989, HEART
[27]   Heart valve function: a biomechanical perspective [J].
Sacks, Michael S. ;
Yoganathan, Ajit P. .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2007, 362 (1484) :1369-1391
[28]   Bioprosthetic heart valve heterograft biomaterials: structure, mechanical behavior and computational simulation [J].
Sacks, Michael S. ;
Mirnajafi, Ali ;
Sun, Wei ;
Schmidt, Paul .
EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (06) :817-834
[29]   On the biomechanics of heart valve function [J].
Sacks, Michael S. ;
Merryman, W. David ;
Schmidt, David E. .
JOURNAL OF BIOMECHANICS, 2009, 42 (12) :1804-1824
[30]   Calcification of tissue heart valve substitutes: Progress toward understanding and prevention [J].
Schoen, FJ ;