On the biomechanical role of glycosaminoglycans in the aortic heart valve leaflet

被引:60
作者
Eckert, Chad E. [1 ]
Fan, Rong [2 ]
Mikulis, Brandon [1 ]
Barron, Mathew [1 ]
Carruthers, Christopher A. [1 ]
Friebe, Vincent M. [3 ]
Vyavahare, Naren R. [3 ]
Sacks, Michael S. [2 ]
机构
[1] Univ Pittsburgh, Swanson Sch Engn, Dept Bioengn, Pittsburgh, PA USA
[2] Univ Texas Austin, Inst Computat Engn & Sci, Dept Biomed Engn, Austin, TX 78712 USA
[3] Clemson Univ, Dept Bioengn, Cardiovasc Implant Res Lab, Clemson, SC USA
关键词
Glycosaminoglycan; Heart valve; Mechanical properties; Mechanical test; MEDIAL COLLATERAL LIGAMENT; BIAXIAL MECHANICAL-PROPERTIES; INTERNAL SHEAR PROPERTIES; STRESS-RELAXATION; BIOPROSTHETIC VALVES; ANTERIOR LEAFLET; HETEROGRAFT BIOMATERIALS; GLUTARALDEHYDE FIXATION; EXTRACELLULAR-MATRIX; FIBER RECRUITMENT;
D O I
10.1016/j.actbio.2012.09.031
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
While the role of collagen and elastin fibrous components in heart valve valvular biomechanics has been extensively investigated, the biomechanical role of the glycosaminoglycan (GAG) gelatinous-like material phase remains unclear. In the present study, we investigated the biomechanical role of GAGs in porcine aortic valve (AV) leaflets under tension utilizing enzymatic removal. Tissue specimens were removed from the belly region of porcine AVs and subsequently treated with either an enzyme solution for GAG removal or a control (buffer with no enzyme) solution. A dual stress level test methodology was used to determine the effects at low and high (physiological) stress levels. In addition, planar biaxial tests were conducted both on-axis (i.e. aligned to the circumferential and radial axes) and at 45 degrees off-axis to induce maximum shear, to explore the effects of augmented fiber rotations on the fiber-fiber interactions. Changes in hysteresis were used as the primary metric of GAG functional assessment. A simulation of the low-force experimental setup was also conducted to clarify the internal stress system and provide viscoelastic model parameters for this loading range. Results indicated that under planar tension the removal of GAGs had no measureable affect extensional mechanical properties (either on- or 45 degrees off-axis), including peak stretch, hysteresis and creep. Interestingly, in the low-force range, hysteresis was markedly reduced, from 35.96 +/- 2.65% in control group to 25.00 +/- 1.64% (p < 0.001) as a result of GAG removal. Collectively, these results suggest that GAGs do not play a direct role in modulating the time-dependent tensile properties of valvular tissues. Rather, they appear to be strongly connected with fiber-fiber and fiber-matrix interactions at low force levels. Thus, we speculate that GAGs may be important in providing a damping mechanism to reduce leaflet flutter when the leaflet is not under high tensile stress. (C) 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:4653 / 4660
页数:8
相关论文
共 58 条
[51]   A METHOD FOR ANALYSIS OF BENDING AND SHEARING DEFORMATIONS IN BIOLOGICAL TISSUE [J].
THUBRIKAR, M ;
EPPINK, RT .
JOURNAL OF BIOMECHANICS, 1982, 15 (07) :529-535
[52]   STRESS-ANALYSIS OF PORCINE BIOPROSTHETIC HEART-VALVES INVIVO [J].
THUBRIKAR, MJ ;
SKINNER, JR ;
EPPINK, RT ;
NOLAN, SP .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (06) :811-826
[53]  
VESELY I, 1993, J THORAC CARDIOV SUR, V106, P288
[54]  
Vesely I, 1998, J BIOMECH, V31, P115, DOI 10.1016/S0021-9290(97)00122-X
[55]   MICROMECHANICS OF THE FIBROSA AND THE VENTRICULARIS IN AORTIC-VALVE LEAFLETS [J].
VESELY, I ;
NOSEWORTHY, R .
JOURNAL OF BIOMECHANICS, 1992, 25 (01) :101-113
[56]   ANALYSIS OF THE BENDING BEHAVIOR OF PORCINE XENOGRAFT LEAFLETS AND OF NATURAL AORTIC-VALVE MATERIAL - BENDING STIFFNESS, NEUTRAL AXIS AND SHEAR MEASUREMENTS [J].
VESELY, I ;
BOUGHNER, D .
JOURNAL OF BIOMECHANICS, 1989, 22 (6-7) :655-&
[57]  
Vyavahare N, 1999, J BIOMED MATER RES, V46, P44
[58]  
Yoon J. H., 2005, Journal of Musculoskeletal & Neuronal Interactions, V5, P22