He-3-MRI of pulmonary ventilation: First clinical applications.

被引:27
作者
Kauczor, HU [1 ]
Ebert, M [1 ]
Kreitner, KF [1 ]
Grossmann, T [1 ]
Nilgens, H [1 ]
Hofmann, D [1 ]
Surkau, R [1 ]
Roberts, T [1 ]
Heil, W [1 ]
Otten, EW [1 ]
Thelen, M [1 ]
机构
[1] UNIV MAINZ,INST PHYS,D-55131 MAINZ,GERMANY
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1997年 / 166卷 / 03期
关键词
lung; MR; contrast enhancement; nuclei other than H; inert gas imaging;
D O I
10.1055/s-2007-1015408
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose of the study is the visualisation of normal pulmonary ventilation in healthy volunteers and the evaluation of abnormalities in patients with different lung diseases using He-3 magnetic resonance imaging (He-3 - MRI). Material and methods: Hyperpolarised He-3 gas (V = 300 ml, p = 3 x 10(5) Pa, polarised to 35-45% by optical pumping, provided in special glass cells) was inhaled by eight healthy volunteers and ten patients with different lung diseases. A 3D FLASH sequence (T-R = 11.8 ms; T-E = 5 ms; matrix 144 x 256, FOV 350 mm, section thickness 7 - 10 mm, coronal orientation) was performed in a single breath-hold (22 - 42 s). Clinical and radiological examinations were available for correlation. Results: The studies were successfully carried out in 8/8 volunteers and in 8/10 patients. The central airways were constantly visualised with intermediate to high signal intensity. The lung parenchyma of volunteers with normal ventilatory function showed Father homogeneous intermediate to high signal, whereas patients with chronic obstructive lung disease and/or pneumonia presented severe signal inhomogeneitises. Space-occupying lesions and pleural effusion caused large areas with little or no signal. The represented the lesion and adjacent ventilatory disturbances whose extent had not been presumed from chest x-ray or CT. The spatial resolution was higher than in Ventilation scintigraphy. Conclusion: He-3 MRI is a promising new modality for the assessment of pulmonary ventilation and its anomalies.
引用
收藏
页码:192 / 198
页数:9
相关论文
共 13 条
[1]   Nuclear magnetic resonance imaging of airways in humans with use of hyperpolarized He-3 [J].
Bachert, P ;
Schad, LR ;
Bock, M ;
Knopp, MV ;
Ebert, M ;
Grossmann, T ;
Heil, W ;
Hofmann, D ;
Surkau, R ;
Otten, EW .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) :192-196
[2]   In vivo He-3 MR images of guinea pig lungs [J].
Black, RD ;
Middleton, HL ;
Cates, GD ;
Cofer, GP ;
Driehuys, B ;
Happer, W ;
Hedlund, LW ;
Johnson, GA ;
Shattuck, MD ;
Swartz, JC .
RADIOLOGY, 1996, 199 (03) :867-870
[3]   NUCLEAR POLARIZATION IN HE-3 GAS INDUCED BY OPTICAL PUMPING AND DIPOLAR EXCHANGE [J].
BOUCHIAT, MA ;
CARVER, TR ;
VARNUM, CM .
PHYSICAL REVIEW LETTERS, 1960, 5 (08) :373-375
[4]   POLARIZATION OF HE3 GAS BY OPTICAL PUMPING [J].
COLEGROVE, FD ;
SCHEARER, LD ;
WALTERS, GK .
PHYSICAL REVIEW, 1963, 132 (06) :2561-&
[5]   Nuclear magnetic resonance imaging with hyperpolarised helium-3 [J].
Ebert, M ;
Grossmann, T ;
Heil, W ;
Otten, WE ;
Surkau, R ;
Leduc, M ;
Bachert, P ;
Knopp, MV ;
Schad, LR ;
Thelen, M .
LANCET, 1996, 347 (9011) :1297-1299
[6]   A DENSE POLARIZED HE-3 TARGET BASED ON COMPRESSION OF OPTICALLY PUMPED GAS [J].
ECKERT, G ;
HEIL, W ;
MEYERHOFF, M ;
OTTEN, EW ;
SURKAU, R ;
WERNER, M ;
LEDUC, M ;
NACHER, PJ ;
SCHEARER, LD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2) :53-65
[7]  
GURNEY JW, 1991, RADIOLOGY, V178, P1
[8]   VERY LONG NUCLEAR-RELAXATION TIMES OF SPIN-POLARIZED HELIUM-3 IN METAL-COATED CELLS [J].
HEIL, W ;
HUMBLOT, H ;
OTTEN, E ;
SCHAFER, M ;
SARKAU, R ;
LEDUC, M .
PHYSICS LETTERS A, 1995, 201 (04) :337-343
[9]  
HEIL W, IN PRESS J NEUTR RES
[10]   Normal and abnormal pulmonary ventilation: Visualization at hyperpolarized He-3 MR imaging [J].
Kauczor, HU ;
Hofmann, D ;
Kreitner, KF ;
Nilgens, H ;
Surkau, R ;
Heil, W ;
Potthast, A ;
Knopp, MV ;
Otten, EW ;
Thelen, M .
RADIOLOGY, 1996, 201 (02) :564-568