Geometry corrections in a rotating 3-dimensional sonographic system

被引:1
作者
Nieckarz, Z
Taton, G
Rokita, E
机构
[1] Jagiellonian Univ, Dept Biophys, PL-31531 Krakow, Poland
[2] Jagiellonian Univ, Inst Phys, PL-31531 Krakow, Poland
关键词
3-dimensional imaging; 3-dimensional reconstruction; 3-dimensional sonography;
D O I
10.7863/jum.2004.23.4.527
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. To devise a system for geometry corrections in a rotating 3-dimensional sonographic system. Methods. A 3-climensional sonographic imaging system based on a standard sonography machine was developed. The transducer mounted in a specially designed holder was rotated about its axis to acquire the spatial information. The most important postulate in rotating 3-climensional systems is the assumption of parallelity between the rotation axis and the transducer axis. It allows the use of simple geometric relationships between 2-dimensional slices in a 3-climensional reconstruction. The errors appearing in the 3-climensional reconstruction when the axes are not parallel were investigated. Results. A simple correction method based on phantom measurements is proposed. The phantom contains a plane, which is inclined to the rotation axis. The analysis of 2-dimensional plane images allows the geometric corrections. The construction of the phantom is described, and the formulas used in the calculations are presented. The method was tested in computer simulations and in patient investigations. Conclusions. A complete method of the geometric investigations and corrections useful in 3-climensional sonographic systems based on rotational geometry is proposed. Both the computer simulations and the phantom measurements confirmed the usefulness, precision, and simplicity of the proposed method.
引用
收藏
页码:527 / 533
页数:7
相关论文
共 8 条
[1]   3-DIMENSIONAL POWER DOPPLER DETECTION OF PROSTATIC-CANCER [J].
DOWNEY, DB ;
FENSTER, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) :741-741
[2]   3-DIMENSIONAL RECONSTRUCTION OF ECHOCARDIOGRAPHIC IMAGES USING THE ROTATION METHOD [J].
GHOSH, A ;
NANDA, NC ;
MAURER, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (06) :655-661
[3]   IN-VIVO COMPARISON OF 3D ULTRASONOGRAPHY AND MAGNETIC-RESONANCE-IMAGING IN VOLUME ESTIMATION OF HUMAN KIDNEYS [J].
GILJA, OH ;
SMIEVOLL, AI ;
THUNE, N ;
MATRE, K ;
HAUSKEN, T ;
ODEGAARD, S ;
BERSTAD, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (01) :25-32
[4]  
LUDOMIRSKY A, 1994, J AM COLL CARDIOL, V23, pA169
[5]  
NELSON TR, 1999, 3 DIMENSIONAL ULTRAS
[6]  
NIECKARZ Z, 2002, EUR J ULTRASOUND
[7]  
Roelandt J R, 1994, J Am Soc Echocardiogr, V7, P217
[8]   Three-dimensional visualization of coronary arteries in excised hearts [J].
Zotz, RJ ;
Zirlik, A ;
Raeder, T ;
Hahn, M ;
Binner, C ;
Ullmann, C ;
Grimm, M ;
Schuler, G .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (01) :11-19