Characterization of a 64 channel PET detector using photodiodes for crystal identification

被引:27
作者
Huber, JS [1 ]
Moses, WW [1 ]
Derenzo, SE [1 ]
Ho, MH [1 ]
Andreaco, MS [1 ]
Paulus, MJ [1 ]
Nutt, R [1 ]
机构
[1] CTI INC,KNOXVILLE,TN 37932
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.596987
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present performance results for a prototype PET detector module consisting of 64 LSO scintillator crystals (3x3x20 mm) coupled on one end to a single photomultiplier tube and on the opposite end to a 64 pixel array of 3 mm square silicon photodiodes (typical pixel parameters are 5 pF capacitance, 300 pA dark current, and 73% quantum efficiency at 415 nm). The photomultiplier tube (PMT) provides an accurate timing pulse and energy threshold for all crystals in the module, the silicon photodiodes (PD) identify the crystal of interaction, the sum (PD+PMT) provides a total energy signal, and the PD/(PD+PMT) ratio determines the depth of interaction. With 32 of the channels instrumented, the detector module correctly identifies the crystal of interaction (where ''correct'' includes the adjacent 4 crystals) 79+/-4% of the time with high detection efficiency. The timing resolution for a single LSO detector module is 750 ps fwhm, while its pulse height resolution at 511 keV is 24+/-3% fwhm. The depth of interaction (DOI) measurement resolution is 8+/-1 mm fwhm.
引用
收藏
页码:1197 / 1201
页数:5
相关论文
共 13 条
  • [1] A DEPTH-ENCODED PET DETECTOR
    BARTZAKOS, P
    THOMPSON, CJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 732 - 738
  • [2] DESIGN OF A HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPH USING SOLID-STATE SCINTILLATION DETECTORS
    CARRIER, C
    MARTEL, C
    SCHMITT, D
    LECOMTE, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 685 - 690
  • [3] CASEY ME, 1997, UNPUB IEEE T NUCL SC, V44
  • [4] A COMPARISON OF PET DETECTOR MODULES EMPLOYING RECTANGULAR AND ROUND PHOTOMULTIPLIER TUBES
    CHERRY, SR
    TORNAI, MP
    LEVIN, CS
    SIEGEL, S
    HOFFMAN, EJ
    ANDREACO, MS
    WILLIAMS, CW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1064 - 1068
  • [5] Algorithms to identify detector Compton scatter in PET modules
    Comanor, KA
    Virador, PRG
    Moses, WW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) : 2213 - 2218
  • [6] CERIUM-DOPED LUTETIUM OXYORTHOSILICATE - A FAST, EFFICIENT NEW SCINTILLATOR
    MELCHER, CL
    SCHWEITZER, JS
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) : 502 - 505
  • [7] MOSES W W, 1991, Journal of Nuclear Medicine, V32, P995
  • [8] PERFORMANCE OF A PET DETECTOR MODULE UTILIZING AN ARRAY OF SILICON PHOTODIODES TO IDENTIFY THE CRYSTAL OF INTERACTION
    MOSES, WW
    DERENZO, SE
    NUTT, R
    DIGBY, WM
    WILLIAMS, CW
    ANDREACO, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1036 - 1040
  • [9] ROOM-TEMPERATURE LSO PIN PHOTODIODE PET DETECTOR MODULE THAT MEASURES DEPTH OF INTERACTION
    MOSES, WW
    DERENZO, SE
    MELCHER, CL
    MANENTE, RA
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1085 - 1089
  • [10] A 16-CHANNEL CHARGE SENSITIVE AMPLIFIER IC FOR A PIN PHOTODIODE-ARRAY BASED PET DETECTOR MODULE
    MOSES, WW
    KIPNIS, I
    HO, MH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1469 - 1472