A systematical analysis of in vivo contact forces on virtual catheter tip/tissue surface contact during cardiac mapping and intervention

被引:111
作者
Okumura, Yasuo [1 ]
Johnson, Susan B. [1 ]
Bunch, T. Jared [1 ]
Henz, Benhur D. [1 ]
O'Brien, Christine J. [1 ]
Packer, Douglas L. [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Internal Med, Div Cardiac Electrophysiol Cardiol, Rochester, MI USA
关键词
catheter ablation; electrophysiology; imaging; mapping; atrial fibrillation;
D O I
10.1111/j.1540-8167.2008.01135.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Contact Forces on Virtual Catheter Tip/Tissue Surface Contact. Introduction: While catheter tip/tissue contact has been shown to be an important determinant of ablative lesions in in vitro studies, the impact of contact on the outcomes of mapping and ablation in the intact heart has not been evaluated. Methods and Results: Twelve dogs underwent atrial ablation guided by the Senesi (TM) robotic catheter remote control system. After intracardiac ultrasound (ICE) validation of contact force measured by an in-line mechanical sensor, the relationship between contact force and individual lesion formation was established during irrigated-tipped ablation (flow 17 mL/sec) at 15 watts for 30 seconds. Minimal contact by ICE correlated with force of 4.7 +/- 5.8 grams, consistent contact 9.9 +/- 8.6 grams and tissue tenting produced 25.0 +/- 14.0 grams. Conversely, catheter tip/tissue contact by ICE was predicted by contact force. A contact force of 10-20 and >= 20 grams generated full-thickness, larger volume ablative lesions than that created with < 10 grams (98 +/- 69 and 89 +/- 70 mm(3) vs 40 +/- 42 mm(3), P < 0.05). Moderate (10 grams) and marked contact (15-20 grams) application produced 1.5 X greater electroanatomic map volumes that were seen with minimal contact (5 grams) (26 +/- 3 cm(3) vs 33 +/- 6, 39 +/- 3 cm(3), P < 0.05). The electroanatomic map/CT merge process was also more distorted when mapping was generated at moderate to marked contact force. Conclusion: This study shows that mapping and ablation using a robotic sheath guidance system are critically dependent on generated force. These findings suggest that ablative lesion size is optimized by the application of 10-20 grams of contact force, although mapping requires lower-force application to avoid image distortions.
引用
收藏
页码:632 / 640
页数:9
相关论文
共 26 条
[1]   Discrepancies between catheter tip and tissue temperature in cooled-tip ablation - Relevance to guiding left atrial ablation [J].
Bruce, GK ;
Bunch, TJ ;
Milton, MA ;
Sarabanda, A ;
Johnson, SB ;
Packer, DL .
CIRCULATION, 2005, 112 (07) :954-960
[2]   Analysis of catheter-tip (8-mm) and actual tissue temperatures achieved during radiofrequency ablation at the orifice of the pulmonary vein [J].
Bunch, TJ ;
Bruce, GK ;
Johnson, SB ;
Sarabanda, A ;
Milton, MA ;
Packer, DL .
CIRCULATION, 2004, 110 (19) :2988-2995
[3]   The effect of ablation electrode length and catheter tip to endocardial orientation on radiofrequency lesion size in the canine right atrium [J].
Chan, RC ;
Johnson, SB ;
Seward, JB ;
Packer, DL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (01) :4-13
[4]   Catheter tip orientation affects radiofrequency ablation lesion size in the canine left ventricle [J].
Chugh, SS ;
Chan, RC ;
Johnson, SB ;
Packer, DL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (03) :413-420
[5]   Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation [J].
Dong, J ;
Dickfeld, T ;
Dalal, D ;
Cheema, A ;
Vasamreddy, CR ;
Henrikson, CA ;
Marine, JE ;
Halperin, HR ;
Berger, RD ;
Lima, JAC ;
Bluemke, DA ;
Calkins, H .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (05) :459-466
[6]  
Eick Olaf J, 2003, Indian Pacing Electrophysiol J, V3, P117
[7]   Initial experience with remote catheter ablation using a novel magnetic navigation system -: Magnetic remote catheter ablation [J].
Ernst, S ;
Ouyang, FF ;
Linder, C ;
Hertting, K ;
Stahl, F ;
Chun, J ;
Hachiya, H ;
Bänsch, D ;
Antz, M ;
Kuck, KH .
CIRCULATION, 2004, 109 (12) :1472-1475
[8]   Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation [J].
Faddis, MN ;
Blume, W ;
Finney, J ;
Hall, A ;
Rauch, J ;
Sell, J ;
Bae, KT ;
Talcott, M ;
Lindsay, B .
CIRCULATION, 2002, 106 (23) :2980-2985
[9]   Atrial linear ablations in pigs - Chronic effects on atrial electrophysiology and pathology [J].
Gepstein, L ;
Hayam, G ;
Shpun, S ;
Cohen, D ;
Ben-Haim, SA .
CIRCULATION, 1999, 100 (04) :419-426
[10]  
HAINES D E, 1991, Journal of Cardiovascular Electrophysiology, V2, P509, DOI 10.1111/j.1540-8167.1991.tb01353.x