摘要
OBJECTIVES The purpose of this study was to evaluate whether multislice computed tomography (MSCT) provides a reliable, noninvasive imaging modality for identification of patients with degenerative aortic valve stenosis (AS) by quantifying the aortic valve area (AVA) in comparison to the accepted diagnostic standard transthoracic echocardiography (TTE). BACKGROUND Management of patients with degenerative AS is based on the severity of disease. The severity of AS in clinical practice is assessed by TTE and classified as mild, moderate, or severe according to the AVA. METHODS Forty-six patients were examined with contrast-enhanced, electrocardiogram-gated, 16-row MSCT for the evaluation of the diagnostic accuracy. In 30 patients, quantification of the AVA with MSCT was compared to TTE using the continuity equation with Doppler velocity-time integral for calculation of the AVA. RESULTS Sensitivity of MSCT for the identification of patients with degenerative AS was 100%, and the specificity was 93.7%. Thirty of 46 patients had AS determined by TTE. Quantification of AVA by MSCT (mean AVA = 0.94 cm(2)) in patients with AS showed a good correlation to TTE (r = 0.89; p < 0.001). Bland-Altman plot illustrated good intermodality agreement between the two methods (limits of agreement, 0.20; 0.29). CONCLUSIONS Multislice computed tomography may provide an accurate, noninvasive imaging technique for detection of patients with AS and quantification of AVA.
引用
收藏
页码:1410 / 1417
页数:8
相关论文
共 21 条
  • [1] Influence of ejection fraction and valvular regurgitation on the accuracy of aortic valve area determination
    Berglund, H
    Kim, CJ
    Nishioka, T
    Luo, H
    Siegel, RJ
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (01): : 65 - 72
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Guidelines for the management of patients with valvular heart disease - Executive summary - A report of the American College of Cardiology American Heart Association task force on practice guidelines (committee on management of patients with valvular heart disease)
    Bonow, RO
    Carabello, B
    de Leon, AC
    Edmunds, LH
    Fedderly, BJ
    Freed, MD
    Gaasch, WH
    McKay, CR
    Nishimura, RA
    O'Gara, PT
    O'Rourke, RA
    Rahimtoola, SH
    Ritchie, JL
    Cheitlin, MD
    Eagle, KA
    Gardner, TJ
    Garson, A
    Gibbons, RJ
    Russell, RO
    Ryan, TJ
    Smith, SC
    [J]. CIRCULATION, 1998, 98 (18) : 1949 - 1984
  • [4] FACTORS AFFECTING DOPPLER ECHOCARDIOGRAPHIC VALVE AREA ASSESSMENT IN AORTIC-STENOSIS
    DANIELSEN, R
    NORDREHAUG, JE
    VIKMO, H
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (15) : 1107 - 1111
  • [5] VALIDATION AND APPLICATIONS OF INDEXED AORTIC PROSTHETIC VALVE AREAS CALCULATED BY DOPPLER ECHOCARDIOGRAPHY
    DUMESNIL, JG
    HONOS, GN
    LEMIEUX, M
    BEAUCHEMIN, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) : 637 - 643
  • [6] New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging
    Flohr, T
    Bruder, H
    Stierstorfer, K
    Simon, J
    Schaller, S
    Ohnesorge, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08): : 1022 - 1027
  • [7] Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality
    Herzog, C
    Abolmaali, N
    Balzer, JO
    Baunach, S
    Ackermann, H
    Dogan, S
    Britten, MB
    Vogl, TJ
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (11) : 2670 - 2678
  • [8] Noninvasive coronary angiography with multislice computed tomography
    Hoffmann, MHK
    Shi, HS
    Schmitz, BL
    Schmid, FT
    Lieberknecht, ML
    Schulze, R
    Ludwig, B
    Kroschel, U
    Jahnke, N
    Haerer, W
    Brambs, HJ
    Aschoff, AJ
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (20): : 2471 - 2478
  • [9] Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT
    Hunold, P
    Vogt, FM
    Schmermund, A
    Debatin, JF
    Kerkhoff, G
    Budde, T
    Erbel, R
    Ewen, K
    Barkhausen, J
    [J]. RADIOLOGY, 2003, 226 (01) : 145 - 152
  • [10] Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation
    Jakobs, TF
    Becker, CR
    Ohnesorge, B
    Flohr, T
    Suess, C
    Schoepf, UJ
    Reiser, MF
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (05) : 1081 - 1086