Long-Term (>10 Years) Clinical Outcomes of First-in-Human Biodegradable Poly-l-Lactic Acid Coronary Stents Igaki-Tamai Stents

被引:193
作者
Nishio, Soji [1 ]
Kosuga, Kunihiko [1 ]
Igaki, Keiji [2 ]
Okada, Masaharu [1 ]
Kyo, Eisho [3 ]
Tsuji, Takafumi [3 ]
Takeuchi, Eiji [4 ]
Inuzuka, Yasutaka [1 ]
Takeda, Shinsaku [1 ]
Hata, Tatsuhiko [1 ]
Takeuchi, Yuzo [1 ]
Kawada, Yoshitaka [1 ]
Harita, Takeshi [1 ]
Seki, Junya [1 ]
Akamatsu, Shunji [1 ]
Hasegawa, Shinichi [1 ]
Bruining, Nico [5 ]
Brugaletta, Salvatore [5 ]
de Winter, Sebastiaan [5 ]
Muramatsu, Takashi [5 ]
Onuma, Yoshinobu [5 ]
Serruys, Patrick W. [5 ]
Ikeguchi, Shigeru [1 ]
机构
[1] Shiga Med Ctr Adults, Dept Cardiol, Moriyama, Shiga 5248524, Japan
[2] Kyoto Med Planning Co Ltd, Kyoto, Japan
[3] Kusatsu Heart Ctr, Shiga, Japan
[4] Shiga Med Ctr Adults, Dept Pathol, Shiga, Japan
[5] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
关键词
angioplasty; coronary artery disease; polymers; prognosis; stents; LARGE 2-INSTITUTIONAL COHORT; SIROLIMUS-ELUTING STENT; QUANTITATIVE-ANALYSIS; FOLLOW-UP; ULTRASOUND; IMPLANTATION; THROMBOSIS; TRIAL; ARTERIES; ABSORB;
D O I
10.1161/CIRCULATIONAHA.110.000901
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The purpose of this study was to evaluate the long-term safety of the Igaki-Tamai stent, the first-in-human fully biodegradable coronary stent made of poly-l-lactic acid. Methods and Results-Between September 1998 and April 2000, 50 patients with 63 lesions were treated electively with 84 Igaki-Tamai stents. Overall clinical follow-up (>10 years) of major adverse cardiac events and rates of scaffold thrombosis was analyzed together with the results of angiography and intravascular ultrasound. Major adverse cardiac events included all-cause death, nonfatal myocardial infarction, and target lesion revascularization/target vessel revascularization. During the overall clinical follow-up period (121 +/- 17 months), 2 patients were lost to follow-up. There were 1 cardiac death, 6 noncardiac deaths, and 4 myocardial infarctions. Survival rates free of all-cause death, cardiac death, and major adverse cardiac events at 10 years were 87%, 98%, and 50%, respectively. The cumulative rates of target lesion revascularization (target vessel revascularization) were 16% (16%) at 1 year, 18% (22%) at 5 years, and 28% (38%) at 10 years. Two definite scaffold thromboses (1 subacute, 1 very late) were recorded. The latter case was related to a sirolimus-eluting stent, which was implanted for a lesion proximal to an Igaki-Tamai stent. From the analysis of intravascular ultrasound data, the stent struts mostly disappeared within 3 years. The external elastic membrane area and stent area did not change. Conclusion-Acceptable major adverse cardiac events and scaffold thrombosis rates without stent recoil and vessel remodeling suggested the long-term safety of the Igaki-Tamai stent.
引用
收藏
页码:2343 / 2352
页数:10
相关论文
共 29 条
[21]   Longitudinal acoustic properties of poly(lactic acid) and poly(lactic-co-glycolic acid) [J].
Parker, N. G. ;
Mather, M. L. ;
Morgan, S. P. ;
Povey, M. J. W. .
BIOMEDICAL MATERIALS, 2010, 5 (05)
[22]   In vivo variability in quantitative coronary ultrasound and tissue characterization measurements with mechanical and phased-array catheters [J].
Rodriguez-Granillo, GA ;
Mc Fadden, EP ;
Aoki, J ;
van Mieghem, CAG ;
Regar, E ;
Bruining, N ;
Serruys, PW .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (01) :47-53
[23]   A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods [J].
Serruys, Patrick W. ;
Ormiston, John A. ;
Onuma, Yoshinobu ;
Regar, Evelyn ;
Gonzalo, Nieves ;
Garcia-Garcia, Hector M. ;
Nieman, Koen ;
Bruining, Nico ;
Dorange, Cecile ;
Miquel-Hebert, Karine ;
Veldhof, Susan ;
Webster, Mark ;
Thuesen, Leif ;
Dudek, Dariusz .
LANCET, 2009, 373 (9667) :897-910
[24]  
Tamai H, 2000, CIRCULATION, V102, P399
[25]   Late Stent Recoil of the Bioabsorbable Everolimus-Eluting Coronary Stent and its Relationship With Plaque Morphology [J].
Tanimoto, Shuzou ;
Bruining, Nico ;
van Domburg, Ron T. ;
Rotger, David ;
Radeva, Petia ;
Ligthart, Jurgen M. ;
Serruys, Patrick W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (20) :1616-1620
[26]   Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries [J].
vanderGiessen, WJ ;
Lincoff, AM ;
Schwartz, RS ;
vanBeusekom, HMM ;
Serruys, PW ;
Holmes, DR ;
Ellis, SG ;
Topol, EJ .
CIRCULATION, 1996, 94 (07) :1690-1697
[27]   Electrocardiogram-gated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three-dimensional reconstruction and automated lumen quantification [J].
vonBirgelen, C ;
Mintz, GS ;
Nicosia, A ;
Foley, DP ;
vanderGiessen, WJ ;
Bruining, N ;
Airiian, SG ;
Roelandt, JRTC ;
deFeyter, PJ ;
Serruys, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (02) :436-443
[28]   Incidence and correlates of drug-eluting stent thrombosis in routine clinical practice -: 4-year results from a large 2-institutional cohort study [J].
Wenaweser, Peter ;
Daemen, Joost ;
Zwahlen, Marcel ;
van Domburg, Ron ;
Jueni, Peter ;
Vaina, Sophia ;
Hellige, Gerrit ;
Tsuchida, Keiichi ;
Morger, Cyrill ;
Boersma, Eric ;
Kukreja, Neville ;
Meier, Bernhard ;
Serruys, Patrick W. ;
Windecker, Stephan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (14) :1134-1140
[29]  
ZIDAR J, 1994, TXB INTERVENTIONAL C, P787