Label free biosensor for sensitive human influenza virus hemagglutinin specific antibody detection using coiled-coil peptide modified microelectrode array based platform

被引:34
作者
Arya, Sunil K. [1 ]
Kongsuphol, Patthara [1 ]
Wong, Chee Chung [1 ]
Polla, Lee Joseph [1 ]
Park, Mi Kyoung [1 ]
机构
[1] Inst Microelect, Singapore 117685, Singapore
关键词
Coiled-coil peptide; HA-antibody; Biosensor; Electrochemical impedance; Self-assembled monolayer; ELECTROCHEMICAL IMMUNOSENSOR; SALMONELLA-TYPHIMURIUM; ELECTRODE; INFECTION;
D O I
10.1016/j.snb.2013.12.066
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Coiled-coil peptide (CCP) modified microelectrode array with comb structure (MACS) has been utilized to fabricate an electrochemical biosensor for antibody detection. Thiol terminated CCP has been employed for self-assembling on MACS and peptide chains connecting amino acid sequence 98-106 (YPYDVPDYA) of human Influenza virus hemagglutinin (HA) has been used as a molecular receptor for HA-antibody. Electrochemical impedance (EIS) studies, cyclic voltammetry studies, atomic force microscopic imaging and contact angle measurements were utilized to characterize self-assembly of CCP on MACS surface. Further, EIS studies were used to investigate interaction between CCP and HA-antibody at different concentrations. EIS measurements revealed that the specific interaction of HA-antibody with CCP gives rise to a clear increase in the value of interfacial charge transfer resistance (R-ct). A linear relationship between R-ct and the logarithm of HA-antibody concentration was found for the concentration range of 1 pg ml(-1) to 100 ng ml(-1), with a detection limit of 1 pg ml(-1). Negligible change of R-ct was observed by incubating the sensor in solutions of other proteins such DO1, anti-GFAP, anti-IL6 and BSA, suggesting high selectivity of descried immunosensor for HA-antibody. These results demonstrated that the CCP modified MACS based platform can provide a versatile matrix for sensitive detection of desired target. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 27 条
[11]   Integrated disposable electrochemical immunosensors for the simultaneous determination of sulfonamide and tetracycline antibiotics residues in milk [J].
Conzuelo, Felipe ;
Campuzano, Susana ;
Gamella, Maria ;
Pinacho, Daniel G. ;
Julio Reviejo, A. ;
Pilar Marco, M. ;
Pingarron, Jose M. .
BIOSENSORS & BIOELECTRONICS, 2013, 50 :100-105
[12]   A label-free electrochemical impedance immunosensor based on AuNPs/PAMAM-MWCNT-Chi nanocomposite modified glassy carbon electrode for detection of Salmonella typhimurium in milk [J].
Dong, Jing ;
Zhao, Han ;
Xu, Minrong ;
Ma, Qiang ;
Ai, Shiyun .
FOOD CHEMISTRY, 2013, 141 (03) :1980-1986
[13]   Electrochemical impedance immunosensor based on gold nanoparticles-protein G for the detection of cancer marker epidermal growth factor receptor in human plasma and brain tissue [J].
Elshafey, Reda ;
Tavares, Ana C. ;
Siaj, Mohamed ;
Zourob, Mohammed .
BIOSENSORS & BIOELECTRONICS, 2013, 50 :143-149
[14]   Recognition of Salmonella typhimurium by immobilized phage P22 monolayers [J].
Handa, Hitesh ;
Gurczynski, Stephen ;
Jackson, Matthew P. ;
Auner, Gregory ;
Walker, Jeremy ;
Mao, Guangzhao .
SURFACE SCIENCE, 2008, 602 (07) :1392-1400
[15]   Impedance Biosensor for Peanut Protein Ara h 1 [J].
Huang, Yin ;
Bell, Melissa C. ;
Suni, Ian I. .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9157-9161
[16]   Nanoparticle-based biosensor for the detection of emerging pandemic influenza strains [J].
Kamikawa, Tracy L. ;
Mikolajczyk, Malgorzata G. ;
Kennedy, Michael ;
Zhang, Pei ;
Wang, Wei ;
Scott, Dorothy E. ;
Alocilja, Evangelyn C. .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (04) :1346-1352
[17]   Mediator and label free estimation of stress biomarker using electrophoretically deposited Ag@AgO-polyaniline hybrid nanocomposite [J].
Kaushik, Ajeet ;
Vasudev, Abhay ;
Arya, Sunil K. ;
Bhansali, Shekhar .
BIOSENSORS & BIOELECTRONICS, 2013, 50 :35-41
[18]   Planar electrochemical sensors for biomedical applications [J].
Laschi, Serena ;
Mascini, Marco .
MEDICAL ENGINEERING & PHYSICS, 2006, 28 (10) :934-943
[19]   Electrochemical impedance spectroscopy for study of aptamer-thrombin interfacial interactions [J].
Li, Xiaoxia ;
Shen, Lihua ;
Zhang, Dongdong ;
Qi, Honglan ;
Gao, Qiang ;
Ma, Fen ;
Zhang, Chengxiao .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) :1624-1630
[20]   Designing heterodimeric two-stranded α-helical coiled-coils -: Effects of hydrophobicity and α-helical propensity on protein folding, stability, and specificity [J].
Litowski, JR ;
Hodges, RS .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2002, 277 (40) :37272-37279