A reagentless electrochemical impedance biosensor for detection of peanut protein Ara h 1, one of the allergenic proteins found in peanuts, has been demonstrated using an Au substrate onto which an antibody film has been immobilized. Following initial stabilization of the self-assembled monolayer (SAM) through which the antibody is immobilized, the biosensor substrate exhibits stable impedance spectra at different stages of substrate preparation. By fitting the impedance spectra to a Randles equivalent circuit, one can demonstrate that the charge-transfer resistance (R-ct) increases and the differential capacitance (C-d) decreases with increasing concentration of Ara h 1, although R-ct exhibits greater sensitivity. The detection limit of this reagentless biosensor is estimated to be less than 0.3 nM. Assuming a Langmuir adsorption isotherm, the dissociation constant of the peanut protein Ara h 1 and its antibody can be calculated as 0.52 nM from the variation in differential capacitance with Ara h 1 concentration.
引用
收藏
页码:9157 / 9161
页数:5
相关论文
共 44 条
[1]   Homology modelling of the major peanut allergen Ara h 2 and surface mapping of IgE-binding epitopes [J].
Barre, A ;
Borges, JP ;
Culerrier, R ;
Rougé, P .
IMMUNOLOGY LETTERS, 2005, 100 (02) :153-158
[2]   On the response of a label-free interferon-γ immunosensor utilizing electrochemical impedance spectroscopy [J].
Bart, M ;
Stigter, ECA ;
Stapert, HR ;
de Jong, GJ ;
van Bennekom, WP .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :49-59
[3]   Chemisorbed poly(propylene sulphide)-based copolymers resist biomolecular interactions [J].
Bearinger, JP ;
Terrettaz, S ;
Michel, R ;
Tirelli, N ;
Vogel, H ;
Textor, M ;
Hubbell, JA .
NATURE MATERIALS, 2003, 2 (04) :259-264
[4]   Capacitance measurements of antibody-antigen interactions in a flow system [J].
Berggren, C ;
Johansson, G .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3651-3657
[5]  
BOCK SA, 1987, PEDIATRICS, V79, P683
[6]   A NONLINEAR LEAST-SQUARES FIT PROCEDURE FOR ANALYSIS OF IMMITTANCE DATA OF ELECTROCHEMICAL SYSTEMS [J].
BOUKAMP, BA .
SOLID STATE IONICS, 1986, 20 (01) :31-44
[7]   Peanut-induced anaphylactic reactions [J].
Burks, W ;
Bannon, GA ;
Sicherer, S ;
Sampson, HA .
INTERNATIONAL ARCHIVES OF ALLERGY AND IMMUNOLOGY, 1999, 119 (03) :165-172
[8]   Label-free protein recognition using an aptamer-based impedance measurement assay [J].
Cai, H ;
Lee, TMH ;
Hsing, IM .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) :433-437
[9]   Polycrystalline gold electrodes: A comparative study of pretreatment procedures used for cleaning and thiol self-assembly monolayer formation [J].
Carvalhal, RT ;
Freire, RS ;
Kubota, LT .
ELECTROANALYSIS, 2005, 17 (14) :1251-1259
[10]  
DIMIZ TB, 2004, ELECTROCHIM ACTA, V49, P4281