Development of an electroless post-processing technique for depositing gold as electrode material on CMOS devices

被引:16
作者
Berdondini, L [1 ]
van der Wal, PD [1 ]
de Rooij, NF [1 ]
Koudelka-Hep, A [1 ]
机构
[1] Univ Neuchatel, Sensors Actuators & Microsyst Lab, Inst Microtechnol, CH-2007 Neuchatel, Switzerland
关键词
high-density microelectrode arrays; electrophysiology; gold electroless; CMOS;
D O I
10.1016/j.snb.2003.12.078
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The limited electrode density and thus, the limited spatial resolution of substrate-integrated microelectrodes arrays (MEAs) used in in-vitro electrophysiology are currently considered as the main constraints of this technique. By taking advantage of the commercially available complementary metal oxide semiconductor (CMOS) standard technology, high density miroelectrode arrays on large active areas could be realized. However, the aluminum alloy used in CMOS as the metallic layer shows poor electrochemical stability in physiological media as well as a poor biocompatibility. A post-processing technique is therefore necessary for depositing a suitable electrode material. The methodology developed in this work relies on a gold electroless deposition technique using commercially available gold cyanide plating solutions. The main advantage of the electroless process is that it needs neither a photolithographic step nor the application of a reduction potential. The electroless process was developed in two stages, to begin with on aluminum-MEAs test structures and then the optimized process was transposed to the CMOS devices. The gold layers were characterized by ESEM, cyclic voltammetry and XPS. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 19 条
[1]   Single-unit neural recording with active microelectrode arrays [J].
Bai, Q ;
Wise, KD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (08) :911-920
[2]  
BERDONDINI L, 2002, C P IEEE EMBS 2 4 MA
[3]   Characterization of the field-effect addressable potentiometric sensor (FAPS) [J].
Böhm, S ;
Parak, WJ ;
George, M ;
Gaub, HE ;
Lorke, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 68 (1-3) :266-273
[4]   Electrical properties of a light-addressable microelectrode chip with high electrode density for extracellular stimulation and recording of excitable cells [J].
Bucher, V ;
Brunner, B ;
Leibrock, C ;
Schubert, M ;
Nisch, W .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) :205-210
[5]   Highly integrated surface potential sensors [J].
George, M ;
Parak, WJ ;
Gaub, HE .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) :266-275
[6]  
Gross GW, 1999, J INTEL MAT SYST STR, V10, P558, DOI 10.1106/XC9U-BMJ8-FE1A-EUNQ
[7]   Plating technology for electronics packaging [J].
Honma, H .
ELECTROCHIMICA ACTA, 2001, 47 (1-2) :75-84
[8]   Rapid substitution of cold for aluminum metallization on integrated circuits [J].
Krasopoulos, AV ;
Li, J ;
Josowicz, M ;
Janata, J .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (03) :1070-1072
[9]  
LACOVANGELO CD, 1991, J ELECTROCHEM SOC, V138, P976
[10]   Significance of inclusions in electroplated gold films for electronics applications [J].
Okinaka, Y .
GOLD BULLETIN, 2000, 33 (04) :117-127