Direct coupling of polymer-based microchip electrophoresis to online MALDI-MS using a rotating ball inlet

被引:43
作者
Musyimi, HK
Guy, J
Narcisse, DA
Soper, SA
Murray, KK
机构
[1] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Ctr BioModular Multi Scale Syst, Baton Rouge, LA 70803 USA
关键词
mass spectrometry; microchip electrophoresis; miniaturization;
D O I
10.1002/elps.200500317
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report on the coupling of a polymer-based microfluidic chip to a MALDI-TOF MS using a rotating ball interface. The microfluidic chips were fabricated by micromilling a mold insert into a brass plate, which was then used for replicating polymer microparts via hot embossing. Assembly of the chip was accomplished by thermally annealing a cover slip to the embossed substrate to enclose the channels. The linear separation channel was 50 mu m wide, 100 mu m deep, and possessed an 8 cm effective length separation channel with a double-T injector (V-inj = 10 nL). The exit of the separation channel was machined to allow direct contact deposition of effluent onto a specially constructed rotating ball inlet to the mass spectrometer. Matrix addition was accomplished in-line on the surface of the ball. The coupling utilized the ball as the cathode transfer electrode to transport sample into the vacuum for desorption with a 355 nm Nd:YAG laser and analyzed on a TOF mass spectrometer. The ball was cleaned online after every rotation. The ability to couple poly(methylmethacrylate) microchip electrophoresis devices for the separation of peptides and peptide fragments produced from a protein digest with subsequent online MALDI MS detection was demonstrated.
引用
收藏
页码:4703 / 4710
页数:8
相关论文
共 36 条
[31]   Sheathless electrospray from polymer microchips [J].
Svedberg, M ;
Pettersson, A ;
Nilsson, S ;
Bergquist, J ;
Nyholm, L ;
Nikolajeff, F ;
Markides, K .
ANALYTICAL CHEMISTRY, 2003, 75 (15) :3934-3940
[32]   Robust and simple interface for microchip electrophoresis-mass spectrometry [J].
Tachibana, Y ;
Otsuka, K ;
Terabe, S ;
Arai, A ;
Suzuki, K ;
Nakamura, S .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1011 (1-2) :181-192
[33]   Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistry [J].
Tüdos, AJ ;
Besselink, GAJ ;
Schasfoort, RBM .
LAB ON A CHIP, 2001, 1 (02) :83-95
[34]   Micro total analysis systems. Recent developments [J].
Vilkner, T ;
Janasek, D ;
Manz, A .
ANALYTICAL CHEMISTRY, 2004, 76 (12) :3373-3385
[35]   Dead volume free micro-machined electro-spray chip for mass spectrometry [J].
Wang, GJ ;
Yang, MW ;
Chang, YZ .
BIOMEDICAL MICRODEVICES, 2004, 6 (02) :159-164
[36]   Electrowetting-based microfluidics for analysis of peptides and proteins by matrix-assisted laser desorption/ionization mass spectrometry [J].
Wheeler, AR ;
Moon, H ;
Kim, CJ ;
Loo, JA ;
Garrell, RL .