A FIA procedure for enzymatic determination of high glucose concentrations. Application to parenteral solutions analysis

被引:5
作者
Barrado, E
Vela, MH
Lapa, RAS
Lima, JLFC
机构
[1] Univ Porto, Fac Farm, CEQUP Dept Quim Fis, P-4050 Porto, Portugal
[2] Univ Valladolid, Fac Ciencias, Dept Quim Analit, Valladolid 47005, Spain
关键词
flow injection analysis; amperometry; glucose; parenteral solutions; Taguchi parameter design; oxidase reaction;
D O I
10.1051/analusis:1999160
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection system for the determination of high levels of glucose in parenteral solutions based on amperometric detection of hydrogen peroxide produced in the glucose oxidase reaction was developed, The determinations were made without any sample pre-treatment. The flow injection manifold includes two dialysis units to perform dilution of the samples and to maintain the enzyme in a closed re-circulation loop. Due to the hydrodynamic characteristics of the analytical system, the variables were optimized using a parameter design of Taguchi. Under optimal conditions, a linear response for glucose concentrations, between 0.1 and 1.0 M was achieved. A good reproducibility (r.s.d. < 3%) and a sampling rate of 30 determinations/hour were observed. The results obtained are in a good agreement with those obtained using the spectrophotometric enzymatic method.
引用
收藏
页码:170 / 174
页数:5
相关论文
共 34 条
[1]  
ALEGRET S, 1987, QUIM ANAL, V6, P278
[2]   INVESTIGATION OF BATCH MEASUREMENTS WITH IMMOBILIZED ENZYME REACTORS AND AMPEROMETRIC ELECTRODES [J].
AMINE, A ;
PALLESCHI, G .
ELECTROANALYSIS, 1995, 7 (08) :785-787
[3]  
Araujo AN, 1997, AM J ENOL VITICULT, V48, P428
[4]   AMPEROMETRIC MICROBIOSENSORS FOR DETECTION OF HYDROGEN-PEROXIDE AND GLUCOSE BASED ON PEROXIDASE-MODIFIED CARBON-FIBERS [J].
CSOREGI, E ;
GORTON, L ;
MARKOVARGA, G .
ELECTROANALYSIS, 1994, 6 (11-12) :925-933
[5]   On-line glucose monitoring by using microdialysis sampling and amperometric detection based on 'wired' glucose oxidase in carbon paste [J].
Csoregi, E ;
Laurell, T ;
Katakis, I ;
Heller, A ;
Gorton, L .
MIKROCHIMICA ACTA, 1995, 121 (1-4) :31-40
[6]   REVERSIBLY IMMOBILIZED GLUCOSE-OXIDASE IN THE AMPEROMETRIC FLOW-INJECTION DETERMINATION OF GLUCOSE [J].
DEALWIS, WU ;
HILL, BS ;
MEIKLEJOHN, BI ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2688-2691
[7]   SPECTROPHOTOMETRIC DETERMINATION OF HYDROGEN-PEROXIDE USING O-HYDROXYHYDROQUINONEPHTHALEIN, TITANIUM(IV) AND ETHYLENEDIAMINETETRAACETIC ACID [J].
FUJITA, Y ;
MORI, I ;
TOYODA, M ;
MATSUO, T .
ANALYTICAL SCIENCES, 1994, 10 (05) :827-830
[8]   Parameters which influence the optimal immobilisation of oxidase type enzymes on methacrylate copolymers as demonstrated for amperometric biosensors [J].
Hall, CE ;
Datta, D ;
Hall, EAH .
ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) :87-96
[9]   NEW AMPEROMETRIC DEHYDROGENASE ELECTRODES BASED ON ELECTROCATALYTIC NADH-OXIDATION AT POLY(METHYLENE BLUE)-MODIFIED ELECTRODES [J].
KARYAKIN, AA ;
KARYAKINA, EE ;
SCHUHMANN, W ;
SCHMIDT, HL ;
VARFOLOMEYEV, SD .
ELECTROANALYSIS, 1994, 6 (10) :821-829
[10]   Prussian-Blue-based amperometric biosensors in flow-injection analysis [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
TALANTA, 1996, 43 (09) :1597-1606